Specifications subject to change without notice
Rev(1)06/2013
www.taitien.com
sales@taitien.com.tw
Page 2of 3
Parameter Min. Typ. Max. Unit Test Condition
-95 -90 dBc/Hz @ 1Hz
-125 -120 dBc/Hz @ 10Hz
-140 -135 dBc/Hz @ 100Hz
-148 -145 dBc/Hz @ 1KHz
2.7.
Phase Noise
-152 -150 dBc/Hz @ 10KHz
3. ELECTRICAL FREQUENCY ADJUSTMENT (PIN = “VCO INPUT”)
Parameter Min. Typ. Max. Unit Test Condition
-0.5 ppm VCO @ Min. Voltage
3.1.
Tuning Range
+0.5 ppm VCO @ Max. Voltage
Referenced to frequency at nominal
Center Voltage
0 +5.0 V
3.2.
Control Voltage
0 +4.0 V
Optional, Refer to Table 1 : Ordering Information
3.3.
Slope Positive
+2.5 V
3.4.
Center Voltage
+2.0 V
Optional, Refer to Table 1 : Ordering Information
Note 1
3.5.
Linearity -10 +10 %
3.6.
Input Impedance 100 kΩ
4. INPUT POWER (PIN = “+VDC”)
Parameter Min. Typ. Max. Unit Test Condition
4.1.
Voltage +4.75 +5.0 +5.25 V
4.2.
Current 800 mA @ turn on
4.3.
Steady State 1.3 W
@ +25°C
5. REFERENCE VOLTAGE (PIN = "REFERENCE VOLTAGE")
(Optional Function. Refer to Table 1 : Ordering Information.)
Parameter Min. Typ. Max. Units Test Condition
5.1.
Voltage
+3.8 +4.0 +4.2 V
5.2.
9 kΩ
Over temperature range in 2.1.
6. ENVIRONMENTAL
Parameter Reference Std. Test Condition
6.1.
Operating Temperature
-40°C to +85°C
Note 2
6.2.
Storage Temperature
-55°C to +105°C
6.3.
Humidity
MIL-STD-202, Method 103
Test Condition A
95% RH @ +40°C,non-condensing,240 hours
6.4.
Vibration (non-operating) MIL-STD-202, Method 201 0.06” Total p-p, 10 to 55 Hz
6.5.
Shock (non-operating)
MIL-STD-202, Method 213,
Test Condition J
30g, 11ms, half-sine
Note 1. When not connected, VCO INPUT is internally held at this voltage.
Note 2. Output maintained over this temperature range. Other requirements of this specification may not be met when operating outside the
temperature range in 2.1.