SGS (Malaysia) Sdn. Bhd. No.26 Jalan Anggerik Vanilla 31/93 Kota Kemuning 40460 S hah Al am, S elangor D arul Ehsan, Malaysia
(Company No. 10871-T) t +6(03) 5121 2320 f +6 (03) 5121 9082 www.sgs.com
Member of the SGS Group (SGS S A)
SGS (MALAYSIA) SDN. BHD.
--------------------------
TAY SIAM PI N E
B.Sc.(HONS) MMIC
ASSISTANT LAB MANAGER
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx . Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advi sed that information cont ained hereon reflects the Comp any’s findings at the time of its in tervention only
and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearan ce of this document is unlawful and offend ers may be prosecuted to the fullest extent of the law. Unless otherwi se stated the results shown in thi s test report refer only to the sample(s)
tested and such sampl e( s) are retained for seven days (peri shable food sample) or three month s only.
Test Report No. CRSSA/23116/16 Date : 30/09/2016 Page: 1 of 13
CRS Ref. CRSSA/16/2183/Tanaka
TANAKA ELECTRONICS (M) SDN BHD
PLOT 11, PHASE IV, BAYAN LEPAS FREE INDUSTRIAL ZONE
11900 PENANG, MALAYSIA
The following merchandise was (were) submitted and identified by the client as:
Sample Description : Au Bonding Wire
Sample Receiving Date : 20/09/2016
Testing Date : 20/09/2016 to 30/09/2016
Date Completed : 30/09/2016
Reporting Date : 30/09/2016
Test Requested : Selected test(s) as requested by client
Test Method : Please refer to next page(s).
Test Results : Please refer to next page(s).
Analysts : Tan Mei Ann, Shirley Then & Leong Ryh Cherng
SGS (Malaysia) Sdn. Bhd. No.26 Jalan Anggerik Vanilla 31/93 Kota Kemuni ng 40460 Sh ah Alam, Selangor Darul Ehsan, Malaysia
(Company No. 10871-T) t +6(03) 5121 2320 f +6 (03) 5121 9082 www.sgs.com
Member of the SG S Group (SGS S A)
SGS (MALAYSIA) SDN. BHD.
--------------------------
TAY SIAM PI N E
B.Sc.(HONS) MMIC
ASSISTANT LAB MANAGER
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx . Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information con tained hereon reflect s the Company’s findings at th e time of its intervention only
and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearan ce of this document is unlawful and offend ers may be prosecuted to the fullest extent of the law. Unless otherwi se stated the results shown in thi s test report refer only to the sample(s)
tested and such sampl e( s) are retained for seven days (perish abl e food sampl e) or three mo nths only.
Test Report No. CRSSA/23116/16 Date : 30/09/2016 Page: 2 of 13
CRS Ref. CRSSA/16/2183/Tanaka
Test results:
Test Part Description :
Sample Description : Au Bonding Wire
RoHS Directive 2011/65/EU Annex II
Test Item(s): Unit Test Method Results MDL Limit
Cadmium (Cd) mg/kg
With reference to IEC 62321-5:2013
(Determination of Cd by ICP-OES)
N.D. 2 100
Lead (Pb) mg/kg
With reference to IEC 62321-5:2013
(Determination of Pb by ICP-OES)
N.D. 2 1000
Mercury (Hg) mg/kg
With reference to IEC 62321-4:2013
(Determination of Hg by ICP-OES)
N.D. 2 1000
Hexavalent Chromium (CrVI) mg/kg
With reference to JIS H 8625, and
performed by UV-VIS Spectrophotometry
N.D. 2 1000
Hexavalent Chromium (CrVI) # µg/cm
2
With reference to IEC 62321-7-1:2015
(Determination of CrVI by UV-VIS)
N.D. 0.10 -
Sum of PBBs
mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. - 1000
Monobromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Dibromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Tribromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Tetrabromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Pentabromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Hexabromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Heptabromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Octabromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Nonabromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -
Decabromobiphenyl mg/kg
With reference to IEC 62321-6:2015
(Determination of PBB by GC-MS)
N.D. 5 -