Basic Switches HS Series
Hermetically Sealed
84HoneywellSensingandControlForapplicationhelp:call1-800-537-6945.
GENERAL INFORMATION
HS switches are designed for applica-
tions where maximum electrical rating
and maximum sealing are essential, and
where size and weight requirements are
less critical. These switches are side
mounted through mounting holes that
are outside the sealed switching cham-
ber.
FEATURES
1
Hermetically sealed per MIL-S-8805,
design symbol 5 (–67
° to +180°For
–55° to 82°C)
1
Power load switching capability up to
25 amperes, 28 VDC or1amp115 VAC
60 Hz
1
Temperature tolerance from –67°Fto
+250°F (–55°Cto+125°C)
1
High temperature construction for use
to +300
°F (149°C)
1
Several styles of integral lever
actuators
1
Two styles of terminals
1
Military standard construction with list-
ings on the MIL-S-8805 qualified prod-
ucts list
1
UL recognized File #E12252; CSA cer-
tified LR 4442
ELECTRICAL RATINGS
Circuitry Electrical Rating Codes
Single-Pole M 25 amps res., 10 amps ind., 5 amps motor, 3 amps
Double-Throw lamp load, 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz
UL-CSA Rating: 1 amp., 115 vac, 60 Hz.
N 15 amps res., 10 amps ind., 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz
O 20 amps res., 10 amps ind., 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz
UL-CSA Rating: 1 amp, 115 vac, 60 Hz
P 10 amps res., 5 amps ind., 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz