More than 6 kV, above the efficiency of the apparatus.
(Notice) This data is made from representative value of a specific lot. The data indicates neither the worst nor guaranteed value.
SCS304A*_MM
Test Result of Electrical Static Discharge (Machine Model) [ Reference Data ]
Products
SiC SBD
Part No.
SCS304A*
Measurement
Instrument
ESS-606 AT-T700
(Noise Laboratory co.,ltd)
Measurement
Condition
C=200 pF   R=0 Ω
T
a
=25
o
C
0%
20%
40%
60%
80%
100%
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
Cumulative Failure Rate
Input Voltage [kV]
K(+)-A(-)
0%
20%
40%
60%
80%
100%
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
Cumulative Failure Rate
Input Voltage [kV]
K(-)-A(+)
2016.11 - Rev.A
More than 6 kV, above the efficiency of the apparatus. More than 6 kV, above the efficiency of the apparatus.
(Notice) This data is made from representative value of a specific lot. The data indicates neither the worst nor guaranteed value.
SCS304A*_HBM
Test Result of Electrical Static Discharge (Human Body Model) [ Reference Data ]
Products
SiC SBD
Part No.
SCS304A*
Measurement
Instrument
ESS-606 AT-T700
(Noise Laboratory co.,ltd)
Measurement
Condition
C=100 pF   R=1.5 kΩ
T
a
=25
o
C 5 pulses
0%
20%
40%
60%
80%
100%
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
Cumulative Failure Rate
Input Voltage [kV]
K(+)-A(-)
0%
20%
40%
60%
80%
100%
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
Cumulative Failure Rate
Input Voltage [kV]
K(+)-A(-)
2016.11 - Rev.A