1024
3L
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
3L
Photocells
V2PC, D2S and EV2IH Series
Cl. I, Div. 2, Groups A, B, C, D
Maintains Cl. I, Div. 2 Suitability of Eaton's
Crouse-Hinds Champ
®
Series Luminaires
The only UL recognized photocells for Class I, Division 2 areas.
Eliminates the need for an explosionproof box!
Eaton's Crouse-Hinds factory-sealed, field installed photocells offer
reliable, dusk-to-dawn lighting control in Class I, Division 2 locations.
These photocells are ideal for walkways, security lighting, and any
other outdoor lighting application that utilizes Champ
®
H.I.D. lighting
luminaires.
Applications:
Eaton's Crouse-Hinds photocells are designed:
• To provide control for automatic dusk-to-dawn lighting.
• For safety by turning on outdoor luminaires in critical passageways
at night.
• To save energy by operating luminaires only when necessary.
• For walkways, parking areas, outdoor process areas, security
lighting, or any outdoor lighting application in Class I, Division 2
locations and corrosive environments.
• For use with LMV, DMV, VMV, VMV High Wattage, and FMV Series
Champ
®
lighting luminaires (V2PC Series).
• For use on 35–400 watt H.I.D., incandescent, or fluorescent
lighting luminaires.
• For remote mounting in FS boxes (D2S Series).
• For mounting in EIH enclosures for Class I, Division 1 applications
(EV2IH Series).
Features:
• Field-installable.
• Solid-state design for performance and dependability.
• Factory sealed components.
Explosionproof enclosure not required for Class I, Division 2
locations.
• Luminaires turn on at 3 footcandles, off at 8 footcandles insuring
that the luminaires are operating only when needed.
• Built-in 10 second time delay to eliminate nuisance tripping.
• Eight-year operating life.
• Furnished with 6" stranded 600 volt color coded wire leads.
• Constructed from corrosion-resistant thermoplastic polyester.
• Available on a DS cover for use with any FS/FD box (D2S Series).
• Available in an EIH enclosure for use in Class I, Division 1, Groups
B*, C, and D locations (EV2IH Series). No seals required.
*For Group B applications, seal within 1
1
/2" of enclosure in accordance with Section 501-5 of
the National Electric Code
®
.
Certifications and Compliances:
V2PC Series and D2S Series
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
• UL Standard: 844 – Hazardous (Classified) Locations
• CSA: C22.2 No. 55
EV2IH Series
• NEC/CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA: 3, 4, 7BCD, 9EFG
• UL Standard: 844 – Hazardous (Classified) Locations
• CSA: C22.2 No. 30, 55
Electrical Rating Ranges:
• 120, 208, 220, 240, 277 VAC
• 50 / 60 Hz
• 35–400 watt H.I.D., incandescent, or fluorescent
• V2PC20 – 3.3A max. current rating
• V2PC22 – 1.8A max. current rating
• V2PC27 – 1.4A max. current rating