MQR075-□F Series
Features
APPlications
Universal AC input/Full range Industrial control system
Protections:short circuit/overload/over voltage/over temperature Semiconductor fabrication equipment
Cooling by free air convection Factory automation
Can be installed on DIN rail TS-35/7.5 or 15 Electro-mechanical apparatus
100% full load burn in-test
3 years warranty
Model Encoding
MQR
-
075
24
F
Model name
Output wattage
Output voltage
Input voltage rating
MQR075-F Series
Specifications
Input
Voltage range Note.1 96-264VAC 120-370VDC
AC current 1.45A/115VAC 0.9A/230VAC
Frequency range 47-63Hz
Inrush current (max) 20A/115VAC 35A/230VAC
Output
DC voltage (V) 12V 24V 48V
Efficiency 84% 87% 88%
Rated Current (A) 6.3A 3.2A 1.6A
Rated power(W) 75.6W 76.8W 76.8W
Voltage ADJ. range ±10%
Ripple & noise(max ) Note.2 80mVp-p 120mVp-p 150mVp-p
Voltage tolerange Note.4 ±2% ±1% ±1%
Line regulation ±0.5% ±0.5% ±0.5%
Load regulation ±1% ±1% ±1%
Setuprise time 1200ms 60ms/230VAC 2000ms 60ms/115VAC(at full load)
Hold up time 60ms/230VAC 12ms/115VAC(at full load)
Status indicator Green LED
Protection
Overload
The rated output power is 105%-130%
Protection mode: Constant current limiting, recovers automatically after fault condition is removed
Over voltage(V)
14-17V 29-33V 56-65V
Protection mode:Shut down O/P voltage ,re-power on to recover
Over temperature Protection mode:Shut down O/P voltage ,re-power on to recover
Safety and EMC
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation resistance I/P-O/P,I/P-FG,O/P-FG :100M Ohms/500VDC/25/70RH
Safety standards Design reference EN IEC 62368-1GB 4943.1
EMC emission
Parameter Standard Test Level/Note
Conducted EN 55032 Class A
Radiated EN 55032 Class A
Voltage Flicker EN 61000-3-3 Design reference Class A
Harmonic Current EN IEC 61000-3-2 Design reference Class A
EMC immunity
Parameter Standard Test Level/Note
ESD EN 61000-4-2
Level 3 8KV air;Level 2 4KV contact
Radiated Susceptibility EN 61000-4-3 Level 2 10V/m
EFT/Burest EN 61000-4-4 Level 3 2KV/5KHZ
Surge EN 61000-4-5
Level 3 2KV/Line-Line;Level3 4kV/Line-Line-
FG
Conducted EN 61000-4-6 Level 3 10V
Magnetic Field EN 61000-4-8 Level 4 30A/m
Voltage Dips and interruptions EN 61000-4-11
<5% residual voltage for 0.5 cycles ,70% residual voltage for 25
cycles ,<5% residual voltage for 250 cycles
Environmental
Working temperature - 20+60 Refer to "Derating curve "
Storage temperature 40+85
Storage humidity 10-95RH
Vibration Component:10-500Hz,2G 10 min/cycle ,60 min each along X,Y,Z axes
MQR075-F Series