Specification
Input
Voltage range
85-264VAC 120-370VDC
AC current
1.5A/115VAC 1.0A/230VAC
Frequency range
47-63Hz
Inrush current (max)
22A/115VAC 44A/230VAC
Output
Chanel
Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2 Ch1 Ch2
DC voltage (V)
5V 12V 5V 24V 12V 24V 5V 48V 12V 48V -5V +5V -12V +12V -15V +15V
Efficiency
80% 83% 83% 84% 84% 80% 82% 82%
Voltage ADJ range
Ch1:4.75-5.5V Ch1:4.75-5.5V Ch1:11.7-12.2V Ch1:4.75-5.5V Ch1:11.7-12.2V Ch1:4.75-5.5V Ch1:11.7-12.2V Ch1:14.6-15.4V
Rated current(A)
7.2A 2A 5.4A 2A 2A 2.1A 5.4A 1A 2.2A 1A 7.5A 7.5A 3.1A 3.1A 2.5A 2.5A
Rated power (W)
60W 75W 74.4W 75W 74.4W 75W 74.4W 75W
Ripple & noise(max )note2
60mVp-p 80mVp-p 60mVp-p 80mVp-p 80mVp-p 80mVp-p 60mVp-p 100mVp-
Voltage tolerance
note3
±2% ±6% ±2% ±8% ±2% ±8% ±2% ±10% ±2% ±10% ±2% ±2% ±2% ±6% ±2% ±6%
Line regulation noite4
±0.5% ±1% ±0.5% ±1% ±0.5% ±1% ±0.5% ±1% ±0.5% ±1% ±0.5% ±1% ±0.5% ±1% ±0.5% ±1%
Load regulation note5
±1.5% ±3% ±1.5% ±3% ±1.5% ±3% ±1.5% ±3% ±1.5% ±3% ±1.5% ±3% ±1.5% ±3% ±1.5% ±3%
Setup, rise time
500ms 50ms/230VAC 1200ms 50ms/115VAC(at full load)
Hold up time
20ms/230VAC 16ms/115VAC(at full load)
Status indicator
Green LED
Protection
Over load
110%-150% of the rated output power
Protection mode:Hiccup mode,recover automatically after fault condition is removed
Over voltage (V)
Ch1:5.6-6.8V Ch1:5.6-6.8V Ch1:13.8-16.2V Ch1:5.6-6.8V Ch1:13.8-16.2V Ch1:5.6-6.8V Ch1:13.8-16.2V Ch1:18-21V
Protection mode:Hiccup mode,recover automatically after fault condition is removed
Three proof treatment Application in dusty and condesation environment
Safety and EMC
Withstand voltage
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Insulation resistance
I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70﹪RH
Safety standards *6 Design refer to EN IEC 62368-1、GB4943.1
EMC emission
Parameter Standard Test level
Conducted EN 55032 Design refer to Class A
Radiated EN 55032 Design refer to Class A
Voltage Flicker EN 61000-3-3 Design refer to Class A
Harmonic Current EN IEC 61000-3-2 Design refer to Class A
EMC immunity
Parameter Standard Test level
ESD EN 61000-4-2 Level 3 8KV air;Level 2 4KV contact
Radiated Susceptibility EN 61000-4-3 Level 2 3V/m
EFT/Burest EN 61000-4-4 Level 3 2KV
Surge EN 61000-4-5
Level 3 2KV/Line-Line;Level3 4kV/Line-Line-FG
Conducted EN 61000-4-6 Level 2 3V
Magnetic Field EN 61000-4-8 Level 2 3A/m
Voltage Dips and interruptions EN 61000-4-11
<
5
%
residual voltage for 0.5 cycles ,70
%
residual voltage for
25 cycles ,<5% residual voltage for 250 cycles:
Environment
Working temperature
﹣25~+60℃(Refer to derating curve diagram)
Storage temperature
﹣20~+85℃
Storage humidity
10-95﹪RH
Vibration resistance
10-500Hz,2G 10Min/Circle 60min in each X,Y,Z direction