For a complete connector overview visit our website www.foc-fo.com.
Connectors MU Connector Standard
Attenuation Element
OAF -MU-PC and OAF -MU-APC
Parameter
Single Mode (PC) Single Mode 8° (APC) Unit
Fibre 9/125 µm
Wavelength 1240 - 1650 nm
InsertionLoss nom. 1 2 3 4 5 6 10 15 20 25 dB
Tolerance* ±0,5 ±0,5 ±0,5 ±0,5 ±0,5 ±0,7 ±0,7 ±1 ±1,5 ±1,5 dB
Repeatibility < 0,5 during live time dB
Durability min. 1000 matings
Return Loss > 50 > 65 dB
Operating
temperature range
-40/+85 °C
* Measured at 1310 und 1550nm. Additional loss from modal noise of 0.05 dB/dB (max.). The 2 transition points of the light may induce a
connector-dependent additional loss of 0.5dB (max.). Other loss values on request.
Application
The attenuation element adjusts the incoming signal level to
the dynamics of the receiver. The attenuation is independent
of the wavelength.
Compatibility
With all LC-PC and LC-APC fiber-optic connectors and adapters
(IEC 61754-20).
OAF- MU-PC body color brown
OAF- MU-APC body color green
Design/Materials
Polishing 0° PC, 8°APC
Ferrule ø 1,25mm, zirconia, rotation locked
Centering sleeve zirconia split, floating
Exterior parts plastic
FOC fibre optical components GmbH
Barbara-McClintock-Str. 5 I 12489 Berlin, Germany
p +49 30 565507-0 I f +49 30 565507-19
w www.foc-fo.com I e info@foc-fo.de
Release 22.04.2020
Subject to modifications
DBE-CON-0214V003
Page 1 of 2
FOC OAF-MU-PC and OAF-MU-APC
Dimensions Standard
5,6
28,9
8,6
FOC fibre optical components GmbH
Barbara-McClintock-Str. 5 I 12489 Berlin, Germany
p +49 30 565507-0 I f +49 30 565507-19
w www.foc-fo.com I e info@foc-fo.de
Release 22.04.2020
Subject to modifications
DBE-CON-0214V003
Page 2 of 2