SUPLET
®
Technical Specification
BBS5N48P14A Series
36Vdc to 75Vdc Input14Vdc / 5A Output
Document No. SLD0R98.A Rev. 1.00 Page 1 of 17
DC-DC Converter
Sixteenth-Brick
RoHS Compliance
Applications
Distributed Power Architectures
Wireless Networks
Access and Optical Network Equipment
Enterprise Networks
Latest generation IC’s (DSP, FPGA, ASIC) and
Microprocessor powered applications
Options
Optional remote On/Off logic
Surface mounting or through-hole
Option trim logic
Features
Compliance with RoHS10 EU Directive
2011/65/EU & 2015/863/EU
Delivers up to 5A output current
�� High efficiency of typ.92% at 14Vout
Industry standard "sixteenth-brick" footprint
Low output ripple and noise
Exceptional thermal performance
High reliability
Remote sense
Remote on/off logic
Monotonic start-up into pre-biased and normal
load
Input under voltage lockout
Output over voltage protection
Output over current protection
Over temperature protection
Short circuit protection
Constant switching frequency (323kHz typical)
Adjustable output voltage: -10% to +10% Vo(nom)
Meets the voltage and current requirements for
ETSI 300-132-2 and is approved for Basic
Insulation rating per IEC60950-1
Description
The BBS5N48P14A series are sixteenth-brick DC/DC converters that provide high efficiency single output. It can operate from
36V to 75V input and 14V/5A output. The output can be trimmed from -10% to +10% of nominal output voltage. The remote
control options are negative logic. The converter turns on when the REM pins are at logic low and turns off when they are at
logic high or left open. The output voltage trim options are positive. The output voltage will increase when the TRIM pins are
connected to “+S” and decrease when connected to “-S”.
Document No. SLD0R98.A Rev. 1.00 Page 2 of 17
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliability.
Parameter Units
Specifications
Notes & conditions
Min. Typ. Max.
Input Voltage Vdc
- - 80 Continuous
- - 100 Transient (100ms)
Operating Temperature -40 - 85
Storage Temperature -55 - 125
Operating Humidity RH(%) 10 - 90 Non-condensing
Storage Humidity RH(%) 10 - 90 Non-condensing
Operating Altitude m 0 - 3000
Storage Altitude m 0 - 3000
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and room temperature
conditions
.
Input Characteristics
Parameter Units
Specifications
Notes & conditions
Min. Typ. Max.
Operating Input Voltage Vdc 36 48 75 Io=0 to Io(max)
Maximum Input Current A - - 3 100%load, Vin=36V
No load Input Current mA - 70 - Vin=Vin(nom), Io=0A
Input Reflected Ripple Current
Peak-to-Peak
mA - - 30
5Hz to 20 MHz,12µH source
inductance