Test Report
No.:
SZXPC23001911605
Date:
Aug 23, 2023
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
Ford Shi
Approved Signatory
Client Name:
GUANGDONG XKB HOLDING CO.LTD
Client Address:
BUILDING 1, NO.36 XINZHOU MIDDLE STREET, LIN VILLAGE, TANGXIA TOWN,
DONGGUAN CITY, GUANGDONG PROVINCE
Sample Name:
Brass
The above sample(s) and information were provided by the client.
---------------------------------------------------------------------------------------------------------------------------------------------
SGS Job No.:
SZPC2308005157
Sample Receiving Date:
Aug 15, 2023
Testing Period:
Aug 15, 2023 ~ Aug 23, 2023
Test Requested:
Select test(s) as requested by the client.
Test Method(s):
Please refer to next page(s).
Test Result(s):
Please refer to next page(s).
Test Requirement
Conclusion
EU RoHS Directive (EU) 2015/863 amending Annex II to Directive
2011/65/EU- Lead, Mercury, Cadmium and Hexavalent chromium
Pass
Test Report
No.:
SZXPC23001911605
Date:
Aug 23, 2023
Test Result(s):
Test Part Description
SN ID
Sample No.
SGS Sample ID
Description
SN1
003
SZX23-0019116-0001.C003
Silvery metal
Remarks:
(1) 1 mg/kg = 1 ppm = 0.0001%
(2) MDL = Method Detection Limit
(3) ND = Not Detected (< MDL)
(4) - = Not Regulated
EU RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU- Lead, Mercury,
Cadmium and Hexavalent chromium
Test Method:
With reference to IEC 62321-4:2013+AMD1:2017, IEC 62321-5:2013 and IEC 62321-7-
1:2015, analysis was performed by ICP-OES and UV-Vis .
Test Item(s)
Limit
Unit(s)
MDL
003
Cadmium(Cd)
100
mg/kg
2
ND
Lead(Pb)
1000
mg/kg
2
130
Mercury(Hg)
1000
mg/kg
2
ND
Hexavalent Chromium (Cr(VI))
-
µg/cm²
0.10
ND
Notes:
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
(2) IEC 62321 series is equivalent to EN 62321 series.
(3) = a. The sample is positive for Cr(VI) if the Cr(VI)concentration is greater than 0.13 μg/cm
2
. The sample
coating is considered to contain Cr(VI)
b. The sample is negative for Cr(VI) if Cr(VI) is ND (concentration less than 0.10 μg/cm
2
). The coating is
considered a non-Cr(VI) based coating
c. The result between 0.10 μg/cm
2
and 0.13 μg/cm
2
is considered to be inconclusive-unavoidable coating
variations may influence the determination.
Information on storage conditions and production date of the tested sample is unavailable and thus Cr(VI) results
represent status of the sample at the time of testing.
Unless otherwise stated, the decision rule for conformity reporting is based on Binary Statement for Simple
Acceptance Rule (w=0) stated in ILAC-G8:09/2019.