DC Interrupting Rating (measured at designated voltage, time constant of less than 50 microseconds, battery source)
DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25
Typical Pre-arcing I
2
t are measured at 10In Current
Circuit Protection
Fast Acting | 2410(6.5x1.6mm)
Brick Fuses
Compatible with reflow
One time positive disconnect
RoHS compliant
Designedd to UL 248-14
Part
Number
Ampere
Rating
(A)
Voltage
Rating
Interrupting
Rating
Typical Cold
Resistance
(mΩ)
Typical
2
Melting I t
2
(A Sec)
Typical
Voltage
Drop (mV)
2410BP-30A-E 30 1.10
1000
50
2410BP Series
Amp Rating % of Amp Rating Opening Time
30A 100% 4 Hours Min.
30A 200%
0sec Max.
Electrical Characteristics
Specification
RoHS
2015/863/EC
2410BP Series fuse for the small size and good electrical
performance, reliability and quality.
72Vdc @ 500A
Dimension
Unit: mm
Packaging
Quantity: 1, 000pcs
12mm tape-and-reel per EIA
Standard 481
.
2.6±0.5
2.6±0.5
Recommended land pattern (mm)
Note: Minimum copper layer thickness = 100um.
Recommend Stencil thickness is 0.15mm
Features
1 of 3
www.prosemitech.com
Specifications are subject to change without notice.
© PROSEMI Document No: POF0520230210001A
Circuit Protection
Fast Acting | 2410(6.5x1.6mm)
Brick Fuses
2410BP Series
Soldering Parameters
Wave Soldering:
260°C, 10 seconds max.
Infrared Reflow:
260°C, 30 seconds max.
Profile Feature
Lead(Pb) free solder
Preheat and soak
Temperature min.(T
smin
)
150
Temperature max. (T
smax
)
200
Time (T
smin
to T
smax
) (t
S
)
60 - 120 Seconds
Average ramp up rate T
smax
to T
p
3 / Second Max.
Liquidous temperature (T
L
) Time at
liquidous (t
L
)
217
60 - 150 Seconds
Peak package body temperature (T
P
)
260
Time (t
P
) within 5 of the specified classification temperature (T
C
)
30 Seconds
Average ramp-down rate (T
P
to T
smax
)
6 / Second Max.
Time (25 to Peak Temperature)
8 Minutes Max.
Infrared Reflow:
260°C, 30 seconds max.
Reflow-Soldering Parameter
Temperature Derating Curve
2 of 3
www.prosemitech.com
Specifications are subject to change without notice.
© PROSEMI Document No: POF0520230210001A
Normal Operating Temperature: 25± 2
Operating Temperature: -55 to 125 with
proper correction factor applied.
Chart of correction factor
Storage Temperature: -55 to 125
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
Factor of Rated Current
-60-50-40-30-20-100102030405060708090100110120130
Ambient Temperature °C