GBU1506 THRU GBU1510
GBU1506 THRU GBU1510
SINGLE PHASE15.0AMPS.GLASS PASSIVATED BRIDGE RECTIFIERS
FEATURE
.UL Listed Under Recognized Component Index,
File Number E338195
.High case dielectric stength
.Low Reverse Leakage Current
.High surge current capability
.Ideal for Printed Circuit Board Applications
MECHANICAL DATA
.Case Material: Molded Plastic.
UL Flammability Classification Rating 94V-0
.Terminals: Pure tin plated, Lead free.
Leads solderable per MIL-STD-750, Method 2026.
.Polarity: Molded on Body
.Mounting: Through Hole for #6 Screw
.Mounting Torque: 5.0 in-lbs Maximum
.RoHS 2.0 Compliant
.Halogen free
SPACING
130(3.2)
45°
Chamfer
~
~
+
-
.906(23.0)
.827(21.0)
.141(3.6)
.130(3.3)
.102(2.6)
.091(2.3)
.024(0.6)
.020(0.5)
.748(19.0)
.709(18.0)
.087(2.2)
.071(1.8)
.748(19.0)
.669(17.0)
.210(5.3)
.190(4.8)
.094(2.4)
.079(2.0)
.150(3.8)
.137(3.5)
.047(1.2)
.039(1.0)
.228(5.8)
.213(5.4)
-
+
AC
Marking
.228(5.8)
.208(5.3)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz,resistive or inductive load. For capacitive load, derate current by 20%
Maximum Recurrent Peak Reverse Voltage
Maximum DC blocking Voltage
Maximum Average Forward (with heatsink Note2)
Rectified Current @ T
C
=100°C(without heatsink)
Peak Forward Surge Current 8.3ms single half
sine-wave superimposed on rate load (JEDEC
method)
Maximum Forward Voltage @15A DC
Drop per element @7.5A DC
Maximum DC Reverse Current @T
J
=25°C
at rated DC blocking voltage @T
J
=125°C
I
2
t Rating for Fusing (t﹤8.3ms)
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance (Note 2)
Operating Junction Temperature
Note:
1. Measured at 1.0 MHz and applied reverse voltage of 4.0Vdc