TIMES
MICROWAVE SYSTEMS
EZ-240-FMH-75
(
stock code: 3190-1613
)
Type F PLUG
Non-solder center contact
Crim
p
-on
(
.255" hex. die
)
outer contact
INSTALLATION INSTRUCTIONS
(Cable Types: LMR-240-75)
1. (A) Trim cable to dimensions shown.
(B) Remove any residual plastic from center conductor.
(C) Deburr center conductor using a fine file or Times
DBT-01 tool.
(D) Avoid nicking aluminum tape.
2. (A) Slide weather seal and crimp ferrule over cable.
(B) Flare braid and insert cable into connector body
until dielectric is seated with all braid wires on
outside of connector body and aluminum tape
inside connector body.
(C) Braid should assemble flush to within 1/16” (.06) of
connector shoulder. Trim excess if necessary.
3. (A) Slide crimp ferrule over braid and crimp as close to
body as possible using hex. die indicated in a Times
HX-4 crimp tool or equivalent. Do not crimp rear of
crimp ferrule.
(B) Heat shrink weather seal over rear of connector
body and down on to cable jacket using hot air gun.
REV-A
SLIGHT CHAMFER
3/16” (.180)
3/4”(.770)
STEP 1
STEP 2
STEP 3
7/16” (.440)
WEATHER SEAL
CRIMP FERRUL
E
TRIM BRAID