(800) TMS-COAX • www.timesmicrowave.com
76
TIMES MICROWAVE SYSTEMS
LMR
®
-195-LLPX
Flexible Low Loss Plenum Coax
Electrical Specications
Performance Property Units US (metric)
Velocity of Propagation % 76
Dielectric Constant NA 1.73
Time Delay nS/ft (nS/m) 1.34 (4.40)
Impedance ohms 50
Capacitance pF/ft (pF/m) 26.7 (87.6)
Inductance uH/ft (uH/m) 0.067 (0.22)
Shielding Effectiveness dB >90
DC Resistance
Inner Conductor ohms/1000ft (/km) 7.6 (24.9)
Outer Conductor ohms/1000ft (/km) 4.9 (16.1)
Voltage Withstand Volts DC 1000
Jacket Spark Volts RMS 3000
Peak Power kW 2.5
Mechanical Specications
Performance Property Units US (metric)
Bend Radius: installation in. (mm) 0.5 (12.7)
Bend Radius: repeated in. (mm) 2.0 (50.8)
Weight lb/ft (kg/m) 0.30 (0.05)
Tensile Strength lb (kg) 40 (18.2)
Flat Plate Crush lb/in. (kg/mm) 10 (0.18)
Construction Specications
Description Material In. (mm)
Inner Conductor Solid BC 0.037 (0.94)
Dielectric Low density PTFE 0.113 (2.87)
Outer Conductor Aluminum Tape 0.119 (3.02)
Overall Braid Tinned Copper 0.142 (3.61)
Jacket Red Fluoropolymer 0.175 (4.45)
• LMR
®
- LLPX is an indoor highly re retardant cable
intended specically for runs within return air handling
plenums (e.g. dropped ceilings, raised oors). It has a
UL/NEC & CSA rating of ‘CMP’ and ‘FT6’ respectively.
• Flexibility and bendability are hallmarks of the LMR-
LLPX cable design. The exible outer conductor
enables the tightest bend radius available for any cable of
similar size and performance.
• Low Loss is another hallmark feature of LMR-
LLPX. Size for size LMR has the lowest loss of any
exible cable and comparable loss to semirigid hard-line
cables.
• RF Shielding is 50 dB greater than typical single
shielded coax (40 dB). The multi-ply bonded foil outer
conductor is rated conservatively at > 90 dB (i.e. >180
dB between two adjacent cables).
• Weatherability: LMR-LLPX cables are designed
for indoor Plenum applications. LMR-LLPX
can also be used for applications that originate
outdoors (e.g., rooftop) and subsequently enter
the building.
• Connectors: A variety of connectors are available for
LMR-LLPX cable, including the most common
interface types. Most employ crimp outer attachment
using standard hex crimp sizes.
• Cable Assemblies: All LMR-LLPX cable types are
available as pre-terminated cable assemblies. Contact
TMS for additional jacket colors
Ideal for…
• Indoor/Outdoor Plenum Feeder runs
• Drop in replacement for RG-142
• UL/NEC/CSA rated CMP/FT6 (listed under UL le #E-170516)
• Any wireless application (e.g. LMDS, MMDS, WLL, GPS, LMR,
WLAN, WISP, WiMax, SCADA, Cellular, PCS, Paging)
requiring an easily routed, low loss RF cable for
in-building systems
LMR-195-LLPX
Environmental Specications
Performance Property
0
F
o
C
Installation Temperature Range -40/+257 -40/+125
Storage Temperature Range -40/+257 -40/+125
Operating Temperature Range -40/+125 -40/+125
Part Description
Stock
Part No. Application Jacket Color Code
LMR-195-LLPX Indoor/Outdoor Plenum Fluoropolymer Red 54425
CMP/FT-6