Article Information Sheet (AIS)
Procell Alkaline Batteries (Major and Specialty Cells)
Consumer Relations: North America
North America: 1-800-551-2355 (9:00 AM - 5:00 PM EST)
2. Company Information
3. Article Information
Procell branded consumer alkaline battery
Electro-technical device
Description
Product Category
Asia
(CN) 4008850883, (HK) 800-969-950, (TW) 0800-251-122, (AU) 1-800-239901, (NZ) 0800-44-
6869, (KP) 080-393-3000, (SG) 800-120-5608, (TH) 001 800 852 6595, (VN) 120 11543, (MY)
1-800-81-5379, (ID)001-803-0167294, (PH) 1-800-1110-1392, (IN) 1800-120-7897
Latin America
(Brazil) 0 800 727 1165, (Chile) 188 800 224 488, (xico) 0 1800 283 2901
(Rest of Latin America) duracell.mx.help
Europe
(UK) 0800 716434, (FR) 0800 346 790 (Service & appel gratuits), (IRL) 1 800 509 176, (DE)
800 101 2112, (AT) 0800 1025 1956, (CH) 0800 000 885, (BE) 0800 509 95, (NL) 0800 265
8616, (IT) 800 125 662, (ES) 900 800 522, (PT) 800 781 012, (GR) 210 66 75 000, (CY) 22-
210900, (DK-FI-NO-SE) +46 8 799 1926, (NO) 63791957, (ZA) 0800980782, (RO) 021
3361915, (IS) +354 5222700, (MD) +373 0800700 88, (BG) 02 40 24 500, (BIH) 033756000,
(MNE) 020261920, (PL) 00800 77628282, (LT) +370 656 40111, (LV) +371 670 48400, (EE)
+3726505555, (CZ) +420 233 325 614, (SK) +42153419601, (HU) 0620 770 7099, (HR) 0800
0009, (SI) 01/588 6800, (AZ) 99412 5990511, (UA) +380444909771 (ПрАТ "САВ 92) &
+380442476704 ОВ «ІНВЕСТКОМ»), (KZ) +7 727 250 05 50, (TM) 00865 530070, (KG) 0312
41 77 04 (Apple City International), (TR) 0 850 502 61 40, (BG)02/40 24 500, (BIH)
38733756000, (UZ) 998 900123313
Consumer Relations:
This Article Information Sheet (AIS) provides relevant battery information to retailers, consumers, OEMs and others users
requesting a GHS-compliant SDS. Articles, such as batteries, are exempt from GHS SDS classification criteria. The GHS criteria is not
designed or intended to be used to classify the physical, health and environmental hazards of an article. Branded consumer
batteries are defined as electro-technical devices. The design, safety, manufacture, and qualification of branded consumer
batteries follow ANSI and IEC battery standards. This document is based on principles set forth in the following hazard
communication approaches: ANSI Z-400.1, GHS, JAMP AIS, IEC 62474, and ANSI C18.4M.
Duracell Industrial Operations, 14 Research Drive, Bethel, CT USA 06801. Duracell Batteries
BV, Nijverheidslaan 7, 3200 Aarschot, Belgium. Duracell International Operations Sàrl, Rue
du Pré-de-la-Bichette 1, CH-1202, Geneva, Switzerland.
www.procell.com
1. Document Information
Global Website
Information Contact
Name & Address
Document ID
Issue Date
Version
Preparer
Last Revision
AIS-Procell ALK
1-May-15
Document Name
2.0
Duracell North America Product Safety & Regulatory
12/7/2022
SDS@duracell.com
Major Cells: AA (LR6), AAA (LR03), C (LR14), D (LR20), 4.5V (3LR12), 9V (6F22, 6LR61)
Portable power source for electronic devices
Procell, Intense, Constant
OEM/OEA
Use
Global sub-brands (Retail)
Global sub-brands (B2B)
Physical Descriptions (IEC
Designations)
Physical Descriptions (IEC
Designations)
Battery Packs: Style- F, Style-B, ILCO
AIS-ALK 1 of 5
Article Information Sheet (AIS)
CAN - NA/Europe/China
Other Non-Active Materials
Applicable Battery Industry
Standards
ANSI C18.1M Part 1, ANSI C18.1M Part 2, ANSI C18.4M, IEC 60086-1, IEC 60086-2, IEC 60086-
5
Remove to fresh air.
A damaged battery will release concentrated and caustic potassium hydroxide.
Do not induce vomiting. Seek medical attention immediately. For information on treatment,
call the National Battery Ingestion Hotline (telephone numbers for the USA and Canada are
provided below).
Flush with water for at least 15 minutes. Seek medical care if irritation persists.
Poison Center/North America
USA/Canada Calls Only: 1-800-498-8666 (Toll Free) [ 24-Hour National Battery Ingestion
Hotline]
Alkaline Manganese Dioxide
Zinc (CAS # 7440-66-6); 10-25%
Manganese Dioxide (CAS # 1313-13-9); 35-40%; Nickel Compounds, Proprietary; 0-6%
Alkali Metal Hydroxide (aqueous potassium hydroxide - CAS # 1310-58-3); 5-10%
Declarable Substances
(IEC 62474 Criteria 1)
5. Health & Safety
Nickel Cobalt Plated Steel or Nickel Plated Steel (CAS # 7440-02-0); 8-15%
None
Exposure to contents inside the sealed battery will not occur unless the battery leaks, is
exposed to high temperatures, or is mechanically abused.
Electro-technical System
Small Cell or Battery
(ANSI C18.1M Part 2; IEC 60086-5)
Sizes: AAA and Specialty Cells fit inside a specially designed test cylinder 2.25 inches
(57.1mm) long by 1.25 inches (31.70 mm) wide.
Required for Small Cell or Battery (Sizes: AAA and Specialty Cells): Keep away from children.
If swallowed, consult a physician immediately.
6. Fire Hazard & Firefighting
Battery Safety Standards & Testing
Duracell batteries meet the requirements of ANSI C18. 1M Part 2 and/or IEC 60086-5. These
standards specify tests and requirements for alkaline batteries to ensure safe operation
under normal use and reasonably foreseeable misuse. The test regimes assess three
conditions of safety. These are:
1-Intended use simulation: Partial use, vibration, thermal shock, and mechanical shock
2-Reasonably foreseeable misuse: Incorrect installation, external short-circuit, free fall
(user-drop), over-discharge, and crush
3-Design consideration: Thermal abuse, mold stress
Precautionary Statements
CAUTION: Batteries may explode or leak, and cause burn injury, if recharged, disposed of in
fire, mixed with a different battery type, inserted backwards or disassembled. Replace all
used batteries at the same time. Do not carry batteries loose in your pocket or purse. Do
not remove the battery label. Keep small batteries (i.e., AAA) away from children. If
swallowed, consult a physician at once.
First Aid - Skin Contact
First Aid - Inhalation
Remove contaminated clothing. Wash skin with soap and water. Seek medical care if
irritation persists.
Electrode - Negative
Electrode - Positive
Electrolyte
Yes
10-15%
First Aid - If swallowed
First Aid - Eye Contact
Batteries may rupture or leak if involved in a fire.
Fire Hazard
Mercury Free Battery
(ANSI C18.4M <5ppm)
Ingestion/Small Parts Warning
Normal Conditions of Use
Note to Physician
Poison Centers/World Directory
http://globalcrisis.info/poisonemergency.html#AAA
4. Article Construction
A battery powers a device by converting stored chemical energy into electrical energy.
Principles of Operation
AIS-ALK 2 of 5