Test Report
Report No: BSTDG1604677371RR-4
Date: Apr.29, 2016
Page 1 of 26
This report shall not be altered,increased or deleted.The results shown in this test report refer only to the sample(s) tested. Without written approval of BST, this test
report shall not be copied except in full and published as advertisement. BST Physical & Chemical Lab.
A1201-1204Xinsanqi Of Dongbao Road, Dongcheng District,
Dongguan, Guangdong, China. E-mail: christina@bst-lab.com
Tel:400-882-9628
Http://www.bst-lab.com
Dongguan BST Testing Co., Ltd.
Fax:86-769-23020106
Complaints hotline:86-755-26747756
Applicant
Address
The following sample(s) was /were submitted and identified on behalf of the clients as
Sample Name
Integrated RJ45 Connector
Discrete Magnetic Transformers
Sample Model
LPJXXXXXXXXXX, LPXXXXXXXX, LPAXXXXXXXX
Sample Received Date
Apr.25, 2016
Testing Period
Apr.25, 2016 To Apr.29, 2016
Test Requested
One hundred and sixty-eight (168 Substances of Very High Concern (SVHC)
Based on the list Published by European Chemicals Agency (ECHA) on Oct.
28, 2008 & Jan. 13, 2010 & Mar.30, 2010 & Jun.18, 2010 & Dec.15, 2010 &
Jun.20, 2011 & Dec.19, 2011 & Jun.18, 2012 & Dec. 19, 2012 & Jun. 20,
2013 & Dec.16, 2013 & Mar. 3, 2014 & Jun. 16, 2014 & Dec. 17, 2014&Jun.
15, 2015&Dec.17, 2015 for public consultation, regarding regulation (EC)
No 1907/2006 concerning the REACH.
Test Method
Please refer to next page(s).
Test Result
Please refer to next page(s).
Signed for and on behalf of
Andy Zheng/ Technical Director
Test Report
Report No: BSTDG1604677371RR-4
Date: Apr.29, 2016
Page 2 of 26
This report shall not be altered,increased or deleted.The results shown in this test report refer only to the sample(s) tested. Without written approval of BST, this test
report shall not be copied except in full and published as advertisement. BST Physical & Chemical Lab.
A1201-1204Xinsanqi Of Dongbao Road, Dongcheng District,
Dongguan, Guangdong, China. E-mail: christina@bst-lab.com
Tel:400-882-9628
Http://www.bst-lab.com
Dongguan BST Testing Co., Ltd.
Fax:86-769-23020106
Complaints hotline:86-755-26747756
Test method and Test equipment:
No.
Test Item
CAS No.
Test Method
Test
Equipment
1
Anthracene
120-12-7
AFPS GS 2014:01 PAK
GC-MS
2
4,4’-Diaminodiphenylmenthane
101-77-9
EN 14362-1:2012
GC-MS
3
Dibuty1 phthalate (DBP)
84-74-2
EN 14372-2004
GC-MS
4
5-tert-buty1-2,4,6-trinitro-m-
Xylene(musk xylene)
81-15-2
EPA 3550C:2007
GC-MS
5
Bis(2-ethyl(phthalate)(DEHP)
117-81-7
EN 14372:2004
GC-MS
6
Hexabromocyclododecane
(HBCDD)
25637-99-4
3194-55-6
(134237-51-7
, 34237-50-6,
134237-52-8)
EPA 3550C:2007
GC-MS
7
Alkanes,C10-13,chloro(Short Chain
Chlorinated Paraffins)
85535-84-8
EPA 8082A:2007
/EPA 8081B:2007
GC-MS
8
Benzyl butyl phthalate (BBP)
85-68-7
EN 14372:2004
GC-MS
9
Bis(tributyltin)oxide
56-35-9
BS ISO 17353:2004
GC-MS
10
Cobalt dichloride
7646-79-9
EPA 3050B:1996
/EPA 3051A:2007
/EPA 3052:1996
ICP-OES
IC-ECD
11
Diarsenic pentaoxide
1303-28-2
EPA 3050B:1996
/EPA 3051A:2007
/EPA 3052:1996
ICP-OES
12
Diarsenic trioxide
1327-53-3
EPA 3052:1996
ICP-OES
13
Triethyl arsenate
15606-95-8
EPA 3052:1996
ICP-OES
14
Lead hydrogen arsenate
7784-40-9
EPA 3050B:1996
/EPA 3051A:2007
/EPA 3052:1996
ICP-OES