2301181397 Errata Update v0.3 for BGM220P
and BGM220S, v0.2 for MGM220P
This notification includes both standard and customer-specific part numbers. An asterisk * represents a number or letter (one or
more) in a customer-specific part number.
The following errata and workarounds have been added or updated:
• Added CUR_E302 (Extra EM1 Current if FPU is Disabled)
• Added DCDC_E302 (DCDC Interrupts Block EM2/3 Entry or Cause Unexpected Wake-up)
• Added EUART_E301 (EUART receiver enters lockup state when using low frequency IrDA mode)
• Added EUART_E302 (Incorrect stop bits lock rx)
• Added IADC_E306 (Changing Gain During a Scan Sequence Causes an Erroneous IADC Result)
• (only BGM220P/S) Added USART_E304 (PRS Transmit Unavailable in Synchronous Secondary Mode)
• (only MGM220P) Updated the workaround in I2C_E303 (I2C Fails to Indicate New Incoming Data)
Links to errata:
BGM220P: https://www.silabs.com/documents/public/errata/bgm220p-errata.pdf
BGM220S: https://www.silabs.com/documents/public/errata/bgm220s-errata.pdf
MGM220P: https://www.silabs.com/documents/public/errata/mgm220p-errata.pdf