Delta InfraSuite PDU
Power Distribution Unit
Rack 1 Rack 2 Rack #
...
For power distribution requirements of medium to large
data centers, Delta’s Power Distribution Unit (PDU)
provides an optimal solution. The space-saving PDC is
easy to move and adapt to future reconfigurations of the
data center. The PDU offers superior power protection
and monitoring, and the flexibility & scalability to match
your actual power distribution requirements. Not only
does it improve availability, it reduces the cost of your
initial investment.
Convenience
• Swappable circuit breakers without tools
• LCD display and keypad for monitoring, setting
parameters
• Recording more than 500 event logs
• Monitoring the current of each branch circuit breaker
• Built-in RS232 interface for remote monitoring
• SNMP interfaces increasing availability
• Cabling from top or bottom
Safety
• Breaker trip alarms
• Breaker over current alarm with alarm threshold
configurable
• Current unbalance and phase sequence error alarm
Availability
• Easy to relocate, reducing investment costs
• Optional transformers for different output voltages
Flexible, easy-to-integrate power
distribution
Technical Specifications
All specifications are subject to change without prior notice.
Delta InfraSuite PDU
Power Distribution Unit
Leaflet_InfraSuite_PDU-275kVA_en-vn_EEAMEC-JY
Model PDC 275
Capacity 275 kVA
Input
Rated Voltage
Voltage Tolerance Range
Frequency
230/400 Vac 3 phase 4 wire+ ground (3P + 100%N + PE)
±15%
50/60 Hz ± 5% (Automatic detection)
Output
Rated Voltage 230Vac 1 phase 2 wire+ ground
±15%Voltage Tolerance Range
Frequency
50/60 Hz ± 5% (Automatic detection)
MCB Branch Type Swappable type
Icu (kA): 10 kA
MCB 32A
MCB 63A
Other MCB
Qty 40 pcs. Brand: Chinehow. Model: CVP-FR-1BA4-32-AB2L2Y-T
Qty 10 pcs. Brand: Chinehow. Model: CVP-FR-1BA4-63-AB2L2Y-T
Configurable
LCD Display System Monitoring and display information, alarms/events with real time,
configure system parameters, alarm parameters, alarm threshold
Input Phase voltage, line voltage, phase current, total power (kW), total energy (kWh),
Over voltage/over current alarm, under-voltage/ under current alarm
Each Output Branch ON/OFF status, phase voltage, current, power, over voltage/over current alarm,
under-voltage. Can set alarm threshold
Conformance Environment CE
Electromagnetic Interference EN55022
Communication Interface RS485/ Modbus-RTU, RJ45/ Modbus-TCP
Dimensions (W x D x H) 600 x 1100 x 2000 mm (standard 19” cabinet)
Weight 225kg
www.deltaww.com | www.deltapowersolutions.com
Delta Group Delta Power Solutions