MODEL NO. SEC-1212
AC INPUT
NOMINAL AC INPUT VOLTAGE
120 VAC (100-130 VAC), 50/60 Hz : Factory Preset, or 230 VAC
(200 - 260 VAC), 50/60 Hz : By internal jumper setting
INPUT CURRENT 2.5 A @ 120 VAC
INPUT CURRENT AT NO LOAD 120 mA ± 10% @120VAC
INRUSH CURRENT AT STARTUP 20A +/- 5A for < 5 ms
DC OUTPUT
OUTPUT VOLTAGE
13.8VDC ± 0.1V
OUTPUT CURRENT Continuous: 10A ; Current Limit: 14A, Auto recovery
OUTPUT NOISE AND RIPPLE
< 150 mV Peak to Peak
PEAK EFFICIENCY 85% +/-5%
DESIGN
TYPE
Switch Mode Power Supply (SMPS) with Fixed Frequency Pulse
Width Modulation (PWM)
OUTPUT SIDE SWITCHING
FREQUENCY
20 KHz
PROTECTIONS
SHORT CIRCUIT, OVERLOAD Constant Current Limiting at 14A ; Auto Reset
OVER VOLTAGE Regulated by PWM Controller
OVER TEMPERATURE Cooled by convection. No protection is necessary
COOLING TYPE OF COOLING Convection – No fan
FUSE
INTERNAL AC SIDE FUSE,
120VAC INPUT
5 mm x 20 mm Glass Fuse ; 250V, 3A, Time Delay Type ;
LittelFuse - “239003”
COMPLIANCE
SAFETY
UL safety listed as “Information Technology Equipment
Power Supply” for USA (UL Standard ANSI/UL-60950-1)
and for Canada (CSA Standard CAN/CSA-C22.2 No. 60950-1)
ELECTRO MAGNETIC INTERFERENCE
EMI – RADIATED & CONDUCTED
FCC Part 15(B), Class B
INPUT / OUTPUT CONNECTIONS
AC INPUT CONNECTION
• “IEC 60320-C14” Inlet Connector on the unit
• Detachable Power Cord with:
- “IEC 60320-C13” Connector on one end
- NEMA5-15P Plug on the other end
DC OUTPUT CONNECTORS
Terminal with Tubular Hole - Diameter 5mm / 0.2” and
set screw (5/64” Hex Socket Head, #10, 24 TPI, 5/16” long)
ENVIRONMENTAL OPERATING TEMPERATURE RANGE 0°C / 32°F to 30°C / 86°F
DIMENSIONS AND WEIGHT
DIMENSIONS (W X D X H) 185 x 208 x 59.5 mm / 7.28 x 8.19 x 2.34 in
WEIGHT 1.36 kg / 3.0 lb