© 2021 SIGLENT TECHNOLOGIES | 1
SSG5000X marker delay command
September 14, 2022
The SIGLENT SSG5000X and X-V RF signal sources have marker outputs on the rear panel that enable
users to have the instrument source signals (markers) at defined points in their output waveform. These
markers can also be delayed in time from the set points using the marker delay function.
From the front panel, the marker delay is located under the ARB > MARKER UTILITIES menu, as shown
below:
For remote programming, the commands were added in firmware revision 1.1.1.2.8 (released 11.14.21),
but were not shown in the SSG5000X Programming Guide (Versions PG0805x_E01B and earlier, as of
09.14.2022).
To Set:
“:IQ:DUALarb:MARKer:DELAy <n>”, where <n> is the time delay and units. For example, to set the delay
to 100 us, send “:IQ:DUALarb:MARKer:DELAy 100us”
To Query:
“:IQ:DUALarb:MARKer:DELAy?”
© 2021 SIGLENT TECHNOLOGIES | 2
North American Headquarters
SIGLENT Technologies America, Inc
6557 Cochran Rd Solon, Ohio 44139
Tel: 440-398-5800
Toll Free:877-515-5551
Fax: 440-399-1211
info@siglent.com
www.siglentamerica.com/
European Sales Offices
SIGLENT TECHNOLOGIES EUROPE GmbH
Staetzlinger Str. 70
86165 Augsburg, Germany
Tel: +49(0)-821-666 0 111 0
Fax: +49(0)-821-666 0 111 22
info-eu@siglent.com
www.siglenteu.com
Asian Headquarters
SIGLENT TECHNOLOGIES CO., LTD.
Blog No.4 & No.5, Antongda Industrial Zone,
3rd Liuxian Road, Bao’an District,
Shenzhen, 518101, China.
Tel:+ 86 755 3661 5186
Fax:+ 86 755 3359 1582
sales@siglent.com
www.siglent.com/ens