Installation of the antenna
nut (36mm, 1
7
/
16
“ AF)
flats (24mm,
15
/
16
“ AF)
Loosen the nut from the shaft.
Remove the slotted washer.
Pass the cables through the hole.
Replace the slotted washer with
stepped face towards hole.
Fasten the nut. Torque: 15 ± 2 Nm.
Use the flats on the antenna shaft to
prevent the antenna from rotating while
fastening.
Connect the cables. Take ESD
precautions! Use cable holders to
avoid tension on the connectors.
The cables can be recessed into the
slot in the shaft to minimize installation
depth.
Cable minimum bending radius: 8mm
(static).
Unused connectors must be terminated.
WAIVER!
It is exclusively in written agreements that we provide our customers with warrants and
representations as to the technical contained specifications and/or the fitness for any
particular purpose. The facts and figures herein are carefully compiled to the best of our
knowledge, but they are intended for general informational purposes only.
HUBER+SUHNER is certified according to ISO 9001 and ISO 14001
HUBER+SUHNER AG
RF Technology
9100 Herisau, Switzerland
Phone +41 (0)71 353 41 11
Fax +41 (0)71 353 47 51
www.hubersuhner.com
DOC-0001152896 Rev. A
HUBER+SUHNER – Excellence in Connectivity Solutions
In the final position of the antenna, the draining hole and the connectors need to be protected against environmental impacts (indoor
environment). Otherwise a cable conduit has to be used.
This product can be returned to HUBER+SUHNER for recycling at the end of its useful life. Please contact your local agent.
General remarks
Page 2 of 2