Keep away from catenary and high voltage lines.
Be careful when working at height!
Always secure ladders!
Always tighten screws!
Caution! ESD (electrostatic discharge) sensitive device.
Always ground yourself while handling the GPS connector.
For more information, see the Security Instruction for
this product on the Huber + Suhner website.
Dimensions in millimeter [mm]
Avoid bringing the cover of the antenna into contact
with acetone, gasoline or oil.
The mounting surface shall be planar and stable.
The material of the mounting surface shall be
steel or aluminium.
Recommended thicknesses of the contact
surface is 8mm (steel) or 12 mm (aluminium).
The height difference between the different
contact surface (each corner area to the center
area) shall be ± 1mm. The height difference
between the closer corner areas shall be ±
0.5mm
indoor
outdoor
Mounting surface
Page 1 of 2
Drilling of threaded holes and cable breakthrough
1. Clear the area where the
bracket is welded from
paint, corrosion or any
anodized layer.
2. Clear this area from any
dust, brake dust, cutting
chip, oil or fat.
Preparation of roof
Cable feedthrough
Use parts of the packaging to
easily position the antenna above
the cable breakthroughas
indicated on the picture.
Feed all cables through the hole.
327.5 ± 0.4
HUBER+SUHNER
SENCITY
RAIL MIMO+ ANTENNA
FOR WIRELESS COMMUNICATION
Mounting Instruction
WAIVER!
It is exclusively in written agreements that we provide our customers with warrants and
representations as to the technical contained specifications and/or the fitness for any
particular purpose. The facts and figures herein are carefully compiled to the best of our
knowledge, but they are intended for general informational purposes only.
HUBER+SUHNER is certified according to ISO 9001 and ISO 14001
HUBER+SUHNER AG
RF Technology
9100 Herisau, Switzerland
Phone +41 (0)71 353 41 11
Fax +41 (0)71 353 47 51
www.hubersuhner.com
Doc. No. 0000813531
Art. No. 92020867
Revision D
HUBER+SUHNER Excellence in Connectivity Solutions
Page 2 of 2
Mounting
Connection of cables
GNSS
TNC - 0.6 Nm
N -1.0 Nm
Connect the cables. Hold the pigtail connectors
during cable attachment. Avoid all tension,
torsion and bending forces.
GNSS Connector (if present):
GNSS without LNA (check product datasheet):
Do not apply a voltage as this antenna is DC
grounded.
GNSS with LNA(check product datasheet):
Take ESD precautions.
Inner conductor: 3…5 V
Outer conductor: GND
Sealing
1)
For a minimum 8mm thick contactsurface, use screws with a
minimum length of 18mm.
For a minimum 12mm thick contactsurface, use screws with a
minimum length of 22mm.
2)
Use mounting screws according to ISO 4762.
Screws are not included.
Place sealing gaskets in the circled
slots in the outer contact surfaces.
Remove the packaging parts and
lowertheantennatowards theroof.
Avoid moving the antenna once it
touches the mounting surface.
Mounting surface
Antenna
Sealant
It is optional to seal the perimeter of the antenna with
sealant.
Avoidto apply sealant to the antenna radome.