To view a full selection of Samlex products visit our website at www.samlexamerica.com or contact us: 1-800-561-5885 or sales@samlexamerica.com
1000W
Model
PST-1000-12
12 VDC- 120 VAC
PST-1000-24
24 VDC- 120 VAC
DC-AC Inverter
Pure Sine Wave
12001-PST-1000-12-24-1119NOTE: Specications are subject to change without notice
Design Features
- High efciency
- 2x surge
- Temperature controlled cooling fan – reduces energy
consumption
- Low RF emissions
- Wide operating DC input range:
10.7 - 16.5 VDC / 21.4 - 33.0 VDC
- Commercial grade design suitable for heavy duty loads, long
periods of continuous operation & for emergency back up
- UPC – Universal Protection Circuit: low voltage, over voltage,
over temperature, over load and short circuit.
- Low idle power draw
- Dual GFCI protected AC outlets
- Optional remote control (sold separately): Model RC-15A
- Comes with pin-type battery cable lugs
- Safety certied to UL & CSA standards, FCC compliant
MODEL NO. PST-1000-12 PST-1000-24
OUTPUT
OUTPUT VOLTAGE 120 VAC ± 3% 120 VAC ± 3%
MAXIMUM OUTPUT CURRENT 8.5A 8.5A
OUTPUT FREQUENCY 60 Hz ± 1% 60 Hz ± 1%
TYPE OF OUTPUT WAVEFORM Pure Sine Wave Pure Sine Wave
TOTAL HARMONIC DISTORTION OF OUTPUT WAVEFORM < 3% < 3%
CONTINUOUS OUTPUT POWER
(At Power Factor = 1) 1000 Watts 1000 Watts
SURGE OUTPUT POWER 2000 Watts (< 8 ms) 2000 Watts (< 8 ms)
PEAK EFFICIENCY > 85% > 85%
AC OUTPUT CONNECTIONS NEMA5-20R GFCI Duplex Outlets NEMA5-20R GFCI Duplex Outlets
INPUT
NOMINAL DC INPUT VOLTAGE 12V 24V
DC INPUT VOLTAGE RANGE 10.7 - 16.5 VDC 21.4 - 33 VDC
MAXIMUM INPUT CURRENT 160A 80A
DC INPUT CURRENT AT NO LOAD < 800 mA < 600 mA
DC INPUT CONNECTIONS Tubular hole diameter: 11 mm / 0.433” ; M8 Set Screw
DISPLAY LED Power, Overload, Over Temperature Power, Overload, Over Temperature
PROTECTIONS
LOW DC INPUT VOLTAGE ALARM 10.7V ± 0.1V 21.4V ± 0.2V
LOW DC INPUT VOLTAGE SHUTDOWN 10V ± 0.1V ; Auto-reset: 11.5V ± 0.3V 20V ± 0.2V ; Auto-reset: 23V ± 0.5V
HIGH DC INPUT VOLTAGE SHUTDOWN 16.5V ; Auto-reset: < 16.5V 33V ; Auto-reset: < 33V
SHORT CIRCUIT SHUTDOWN When output voltage drops to 80V or lower for up to 2.5 sec
OVERLOAD SHUTDOWN At overload of 110% to 115% for 2 to 2.5 sec
GROUND FAULT SHUTDOWN Through GFCI outlets (5 to 6 mA leakage)
OVER TEMPERATURE SHUTDOWN 90°C ± 5°C ; Auto reset at 65°C ± 5°C
REVERSE POLARITY ON DC INPUT SIDE External / internal DC sides fuses will blow
REMOTE WIRED REMOTE CONTROL (OPTIONAL) RC-15A (sold separately) with 15’ cable
COOLING FORCED AIR COOLING
Temperature controlled fan
Fan ON at 55°C ± 3°C; Fan OFF at 45°C ± 3°C
COMPLIANCE
SAFETY
Intertek - ETL Listed. Conforms to ANSI/UL Standard 458 and certied to
CSA Standard C22.2 No. 107.1-01
EMI / EMC FCC Part 15(B), Class B
ENVIRONMENT OPERATING TEMPERATURE RANGE
Operating temperature -20 to 40C / -4 to 104F
Storage temperature -30 to 70C / -22 to 158F
90% relative humidity non-condensing
DIMENSIONS
(W X D X H), MM 238 x 397 x 82 238 x 397 x 82
(W X D X H), INCHES 9.37 x 15.63 x 3.23 9.37 x 15.63 x 3.23
WEIGHT
KG 4.0 4.0
LBS 8.8 8.8
3 YEAR LIMITED WARRANTY