Data Sheet for Linear Sensors
MEGATRON Elektronik GmbH & Co. KG ▪ Hermann-Oberth-Strasse 7 ▪ 85640 Putzbrunn / Munich
Tel.: +49 89 46094-0 ▪ www.megatron.de ▪ info@megatron.de
Date: 11/08/2021
Page: 1 of 3
Potentiometric Linear Transducer (Conductive Plastic)
Series CD18
Specications are subject to change without notice
Electrical Data
CD18 25 CD18 50 CD18 75 CD18 100 CD18 150
Eective electrical travel 1.)
25 +3 mm 50 +3 mm 75 +3 mm 100 +3 mm 150 +3 mm
Total electrical travel 1.) 26 ±1 mm 51 ±1 mm 76 ±1 mm 101 ±1 mm 151 ±1 mm
Total resistance 1.) 1 kOhm 5 kOhm
Resistance tolerance ±20 %
Independent linearity (best straight line) 1.) ±0.2 % ±0.1 % ±0.05 %
Theoretical resolution 1.)
Almost innite
Backlash (Hysteresis) 1.)
≤ 0.02 mm
Max. / recommended wiper current1.)
1 mA (@40 °C, 1 min in case of failure) / 2 µA
Power rating @40 °C (0 W @120 °C)
≤ 0.6 W ≤ 1.2 W ≤ 1.8 W ≤ 2.5 W ≤ 3.6 W
Isolation voltage 1.)
< 100 μA@500 VAC, 1bar, 2s
Isolation resistance 1.)
100 MOhm@500 VDC, 1bar, 2s
Mechanical Data, Environmental Condi-
tions, Miscellaneous
CD18 25 CD18 50 CD18 75 CD18 100 CD18 150
Mechanical stroke 1.) 30 mm 55 mm 80 mm 105 mm 155 mm
Lifetime (90 % eective electrical travel) 2.)
> 25 million meters or 100 million movements
(the smaller value applies)
Max. operational speed < 10 m/s
Operational force @ RT 1.) 2.) < 0.3 N
Operational temperature
-30..+100 °C
Storage temperature
-50..+120 °C
Protection grade (IEC60529)
IP40
Vibration (IEC 68-2-6, Test Fc)
20 g (5..2000 Hz, 0.75 mm)
Shock (IEC 68-2-27, Test Ea)
50 g, halfsine, 11 ms (18x)
Housing length 63 ±1 88 ±1 113 ±1 138 ±1 188 ±1
Mass
ca. 83 g ca. 102 g ca.121 g ca. 140 g ca. 178 g
Mounting parts (included in delivery)
4 x mounting clamps
Material housing
Aluminium
Material pushrod
Stainless steel
Connection type Round cable 3-pole 1 m, plug DIN 43322
1.) According IEC 60393
2.) Determined by climatic conditions according to IEC 68-1, para. 5.3.1 without load collectives
Please note: Max. permissible supply voltage <75 VDC respectively <50 VAC in addition the max. power rating must be observed
The linear potentiometers of the CD18 series have a guided
push rod on both sides and are available in measuring
strokes from 25..150 mm. The sensors have a coupling
(WKM8 1 piece included), which makes assembly easier
and compensates lateral misalignment. The delivery
includes a set of mounting clamps.
With connector
With cable