Data Sheet for Linear Sensors
MEGATRON Elektronik GmbH & Co. KG ▪ Hermann-Oberth-Strasse 7 ▪ 85640 Putzbrunn / Munich
Tel.: +49 89 46094-0 ▪ www.megatron.de ▪ info@megatron.de
Date: 11/08/2021
Page: 1 of 3
Potentiometric Linear Transducer (Conductive Plastic)
Series CFL
Specications are subject to change without notice
The CFL series has a high-resolution conductive
plastic resistance element with cursor for measuring
strokes 100..1000 mm.
Electrical Data
CFL 100 CFL 200 CFL 300 CFL 400 CFL 500 CFL 700 CFL1000
Eective electrical travel 1.) 100 ±1 200 ±1 300 ±1 400 ±1 500 ±1 700 ±1 1000 ±1
Total resistance 1.) 2..10 kOhm
5..20
kOhm
5..100 kOhm
10..200
kOhm
10..500
kOhm
Resistance tolerance ±20% (±10%)
Independent linearity (best straight line) 1.) ±0,5% (±0,1%)
Theoretical resolution 1.) Almost innite
Backlash (Hysteresis) 1.) ≤ 0,1 mm
Max. / recommended wiper current1.) 1 mA (@ 40°C, 1 min in case of failure) / 2 µA
Power rating @ 70°C (0W @ 105°C) ��� 1 W ≤ 2 W ≤ 2,5 W ≤ 3 W ≤ 4 W ≤ 5 W ≤ 6 W
Isolation voltage 1.) 500 VAC, 1min
Isolation resistance 1.) 1000 MOhm @ 500 VDC
Mechanical Data, Environmental
Conditions, Miscellaneous
CFL 100 CFL 200 CFL 300 CFL 400 CFL 500 CFL 700 CFL1000
Mechanical stroke 1.) in mm
ca. 103 ca. 203 ca. 303 ca. 403 ca. 505 ca. 705 ca. 1005
Lifetime (90% eective electrical travel) 2.) 20 Mio. movements
Max. operational speed < 5 m/s
Operational force @ RT 1.) 2.) < 0,2 N
Operational temperature
-30..+105°C
Storage temperature
-30..+105°C
Protection grade (IEC60529)
IP40
Vibration (IEC 68-2-6, Test Fc)
15 g (10..2000 Hz, 0,75mm, 12h)
Shock (IEC 68-2-27, Test Ea)
50 g, halfsine, 11 ms (18x)
Housing length 150 ±1 250 ±1 350 ±1 450 ±1 550 ±1 750 ±1 1050 ±1
Mass
50 g 70 g 100 g 130 g 160 g 230 g 300 g
Mounting parts (included in delivery)
None
Material housing
Aluminium
Electrical connection
Soldering pins
1.) According IEC 60393
2.) Determined by climatic conditions according to IEC 68-1, para. 5.3.1 without load collectives
Please note: Max. permissible supply voltage <75 VDC respectively <50 VAC in addition the max. power rating must be observed