Data Sheet for Linear Sensors
MEGATRON Elektronik GmbH & Co. KG ▪ Hermann-Oberth-Strasse 7 ▪ 85640 Putzbrunn / Munich
Tel.: +49 89 46094-0 ▪ www.megatron.de ▪ info@megatron.de
Date: 11/08/2021
Page: 1 of 3
Potentiometric Linear Transducer (Conductive Plastic)
Series CLP13 / CLPR13
Specications are subject to change without notice
CLP13
CLPR13
Mechanical Data, Environmental Condi-
tions, Miscellaneous
CLP(R)13-13 CLP(R)13-25 CLP(R)13-50 CLP(R)13-100
Mechanical stroke 1.)
12,7 +3 mm 25,4 +3 mm 50,8 +3 mm 101,6 +3 mm
Lifetime (90% eective electrical travel) 2.) 40 / 20 Mio. movements (CLP13 / CLPR13)
Max. operational speed < 5 m/s
Operational force @ RT 1.) 2.) (CLP / CLPR) < 0,5 N / 3,5 N < 0,5 N / 5 N < 1 N / 5 N
End stop force in case of failure
< 20 N
Operational temperature
-30..+105°C
Storage temperature
-30..+105°C
Protection grade (IEC60529)
IP40
Vibration (IEC 68-2-6, Test Fc)
15 g (10..2000 Hz, 0,75mm, 12h)
Shock (IEC 68-2-27, Test Ea)
50 g, halfsine, 11 ms (18x)
Housing length
38 ±1 mm 51 ±1 mm 76 ±1 mm 127 ±1 mm
Mass
ca. 10 g ca. 15 g ca. 25 g ca. 35 g
Mounting parts (included in delivery)
None
Material housing
Plastic
Material push rod
Stainless steel
Connection type Soldering pins
The CLP13 / CLPR13 series is used in applications
where a displacement sensor with space saving design
is required.
Linear potentiometer (conductive plastic) with almost
innite resolution
Measuring lengths from 13 mm to 100 mm
Compact dimensions
Long lifespan (up to 40 million movements)
With and without spring return
The compact displacement sensor has an excellent lifetime
due to the Comolded conductive plastic technology. The
front guided push rod allows use in applications with limited
overall length. The spring return opens up additional elds
of application.
Electrical Data
CLP(R)13-13 CLP(R)13-25 CLP(R)13-50 CLP(R)13-100
Eective electrical travel 1.)
12,7 ±0,5 mm 25,4 ±0,5 mm 50,8 ±0,5 mm 101,6 ±0,5 mm
Total resistance 1.) 0,5, 1, 2, 5, 10 kOhm 1, 2, 5, 10, 20 kOhm
Resistance tolerance ±10%
Independent linearity (best straight line) 1.) ±1% (±0,5%) ±0,7% (±0,5%) ±0,5% (±0,3%) ±0,3% (±0,1%)
Theoretical resolution 1.)
Almost innite
Backlash (Hysteresis) 1.)
≤ 0,1 mm
Max. / recommended wiper current 1.)
1 mA (@ 40°C, 1 min in case of failure) / 2 µA
Power rating @ 70°C (0W @ 105°C)
≤ 0,2 W ≤ 0,4 W ≤ 0,7 W ≤ 1,2 W
Isolation voltage 1.)
500 VAC, 1min
Isolation resistance 1.)
1000 MOhm @ 500 VDC
1.) According IEC 60393
2.) Determined by climatic conditions according to IEC 68-1, para. 5.3.1 without load collectives
Please note: Max. permissible supply voltage <75 VDC respectively <50 VAC in addition the max. power rating must be observed