Ceramic Plate Series CP2-31-06-L1-W4.5
MFG Part Number: 57125-501
The CP2-31-06-L1-W4.5 is a high-performance and highly reliable
standard Thermoelectric Cooler. Assembled with Bismuth Telluride
semiconductor material and thermally conductive Aluminum Oxide
ceramics. It has a maximum Qc of 28.8 Watts when ΔT = 0 and a
maximum ΔT of 70.5 °C at Qc = 0.
Ceramic Plate Series Thermoelectric Cooler
Features
Compact geometric sizes
DC Operation
RoHS-compliant
Applications
Thermoelectric Coolers for Reagent Storage
Thermoelectric Coolers for Handheld Cosmetic Lasers
Cooling for Centrifuges
Heads-Up Displays, Imaging Sensors
Peltier Cooling for Machine Vision
ELECTRICAL AND THERMAL PERFORMANCE
For maximum performance, be sure to orient the CONTROL side of the TEC against the application to be managed and the HEATSINK side against the heat sink or other heat
rejection method. The CONTROL side is always opposite the side with lead attachments. Lead attachment is a passive heat loss and less impactful if located on the side that attaches
to the heat exchanger.
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00
Operating Current (Amps)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
Operating Voltage (Volts)
Current vs Voltage (I vs V)
Thot = 27 °C
ΔT=0°C
ΔT=10°C
ΔT=20°C
ΔT=30°C
ΔT=40°C
ΔT=50°C
ΔT=60°C
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00
Operating Current (Amps)
0.00
5.00
10.00
15.00
20.00
25.00
30.00
35.00
Qc (Watts)
Heat Pumped at Cold Side
Thot = 27 °C
ΔT=0°C
ΔT=10°C
ΔT=20°C
ΔT=30°C
ΔT=40°C
ΔT=50°C
ΔT=60°C
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00
Operating Voltage (Volts)
0.00
5.00
10.00
15.00
20.00
25.00
30.00
35.00
Qc (Watts)
Heat Pumped at Cold Side
Thot = 27 °C
ΔT=0°C
ΔT=10°C
ΔT=20°C
ΔT=30°C
ΔT=40°C
ΔT=50°C
ΔT=60°C
Ceramic Plate Series CP2-31-06-L1-W4.5
MFG Part Number: 57125-501
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00
Operating Current (Amps)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
COP
Coefficient of Performance (COP = Qc/Pin)
Thot = 27 °C
ΔT=0°C
ΔT=10°C
ΔT=20°C
ΔT=30°C
ΔT=40°C
ΔT=50°C
ΔT=60°C
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00
Operating Voltage (Volts)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
COP
Coefficient of Performance (COP = Qc/Pin)
Thot = 27 °C
ΔT=0°C
ΔT=10°C
ΔT=20°C
ΔT=30°C
ΔT=40°C
ΔT=50°C
ΔT=60°C
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00
Operating Current (Amps)
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
90.00
Qh (Watts)
Total Heat Dissipated at Hot Side (Qh=Qc+Pin)
Thot = 27 °C
ΔT=0°C
ΔT=10°C
ΔT=20°C
ΔT=30°C
ΔT=40°C
ΔT=50°C
ΔT=60°C
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00
Operating Voltage (Volts)
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
90.00
Qh (Watts)
Total Heat Dissipated at Hot Side (Qh=Qc+Pin)
Thot = 27 °C
ΔT=0°C
ΔT=10°C
ΔT=20°C
ΔT=30°C
ΔT=40°C
ΔT=50°C
ΔT=60°C
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0
ΔT (°C)
0.00
5.00
10.00
15.00
20.00
25.00
30.00
Qc (Watts)
Heat Pumped at Cold Side (Qc)
Thot = 27 °C | Current = 12.1 Amps
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0
ΔT (°C)
0.00
0.50
1.00
1.50
2.00
COP
Coefficient of Performance (COP = Qc/Pin)
Thot = 27 °C | Current = 12.1 Amps