Venus power supply module
--------------------------------------------------------------------------------
Date of issue: March 20, 2005 Product model: V series
1. Lead wires
Red wire: positive terminal of input power supply; black wire: ground wire of input power supply;
green wire: control terminal of output voltage; white wire: HV output
2. Main technical parameters
1Working temperature range: -55+125
2Input power supply voltage: +VCC+0V~+18V
3Input power supply current: less than 150mA
4Input control voltage: +0V~+ VCC
5Control voltage input resistance: 150K
6Output voltage: 0~+1800V
7Output current: 1mA
8Output ripple: 200mVp-p typical 100mVp-p.(with recommended filter: 5mVp-p; typical
1mVp-p.)
9Temperature stability: lower than ±40PPM/0 Ctypical±20PPM/0 C
10Load adjusting rate: ±0.05(50% load change)
11Linear adjusting rate: ±0.1%(10% linear change)
12Shock resistance: 25G0~300Hz
13Output characteristic: the magnification times 100 relationship exists between the output voltage
control terminal voltage and the output voltage.
14Mechanical dimension:
3. Operating requirement
1In some case for convenient wiring, the green wire and red wire can be wired together, then
connected to the control terminal that can supply power just for the purpose of executing control and
energy supply at the same time. However, when using this control mode for 0~+500V output, the
relationship between output voltage and the control voltage is not exact the magnification times 100
relationship.
2If power output is greater than 600μA and using the control mode to wire the green wire and red
wire together, the magnification relationship between the output voltage control terminal voltage and
the output voltage might be less than 100. The greater the power output, the smaller the magnification
times.
3 Never let the environmental temperature be higher than the highest working temperature of the
module for a long time. The module can work reliably for a long time without any heat damage within
rated working temperature range. The maximum laboratory time is 200h continuous working. However,
after working environmental temperature is higher than the rated working temperature, the damage and
aging of elements, devices and materials would speed up.
4If it is required to make the HV output ripple smaller for application, just wire a RC filter using
the self-contained resistances and HV capacitances; in such way, the ripple can be less than 1 mVp-p in
general. See the attached drawing for the wiring method for the RC filter.
4. Recommended filter wiring method: