Brüel & Kjær Vibro A/S
2850 Nærum Denmark
Tel.: +45 7741 2500
Fax: +45 45 80 2937
E-mail: info@bkvibro.com
Brüel & Kjær Vibro GmbH
64293 Darmstadt Germany
Tel.: +49 (0) 6151 428 1100
Fax: +49 (0) 6151 428 1200
E-mail: info@bkvibro.com
Date: 29. Mar. 2010
www.bkvibro.com
VIBROCONTROL 1100
Safety and reliability related values according to DIN EN ISO 13849-1
Safety and reliability related values MTTF, PL and Category according to DIN EN ISO 13849-1 have been
evaluated for VC-1100 with the following results:
Device: VC-1100 C01 and C11
Parameter
Value (40°C)
Value (50°C)
MTTF
640.148 h
~ 73 years
414.950 h
~ 47 years
PL
c
c
Category
1
1
Device: VC-1100 C02 and C12
Parameter
Value (40°C)
Value (50°C)
MTTF
696.209 h
~ 79 years
541.741 h
~ 62 years
PL
c
c
Category
1
1
Device: VC-1100 C01/CCS and C11/CCS
Parameter
Value (40°C)
Value (50°C)
MTTF
638.674 h
~ 73 years
414.143 h
~ 47 years
PL
c
c
Category
1
1
Device: VC-1100 C02/CCS and C12/CCS
Parameter
Value (40°C)
Value (50°C)
MTTF
694.466 h
~ 79 years
540.784 h
~ 62 years
PL
c
c
Category
1
1
Test conditions:
Operating temperatures: 40°C und 50°C.
Environmental conditions: G r ound Benign, Controlled
Brüel & Kjær Vibro A/S
2850 Nærum Denmark
Tel.: +45 7741 2500
Fax: +45 45 80 2937
E-mail: info@bkvibro.com
Brüel & Kjær Vibro GmbH
64293 Darmstadt Germany
Tel.: +49 (0) 6151 428 1100
Fax: +49 (0) 6151 428 1200
E-mail: info@bkvibro.com
Date: 29. Mar. 2010
www.bkvibro.com
Note:
The results of this assessment are valid when the following procedures are followed:
The Relays of the VC-1100 have to be operated in the „normally energised” mode.
The analog 4-20 mA signal industry-standard current loops must be used.
The OK Relay has to be used as system function.
The VC-1100 system must be protected against erroneous change in configuration
Abbreviations:
MTTF
PL
Category
Classification of the safety related parts of a control system in respect of their
resistance to faults and their subsequent behaviour in the fault condition, and
which is achiev ed b y the structur al arr ang ement of the parts, fault detection
Ground Benign,
Controlled
Note:
The harmonized standard EN 954-1 is stil l va lid (end of 2011), but it is considered technically outdated. It
was replaced by the current harmonized standards EN ISO 13849-1. More detailed information about safety
and reliability values can be obtained on request from Brüel & Kjær Vibro (
info@bkvibro.com).
Internet/Ha En/Saf ety & Reliability VC-1100