Confidential C
QKE-DFFDE09-02 Rev.9
Document No.
1
Technical Report
CABLINE
®
-SS
The simulation of passing PLUG through hinge
IER-001-10262-00EN
Part No. Plug: 20380-#**T-##
0 R21109 2021/02/22 R. Hatano T.Tanigawa H. Ikari
Rev. ECN Date Prepared by Checked by Approved by
2
Confidential C
Document No.
CABLINE-SS The simulation of passing PLUG through hinge IER-001-10262-00EN
1. Purpose
We report the simulation results of the minimum diameter of the hinge that can store the connector(CABLINE-SS Plug) and cable.
2. Simulation conditions
Connector : CABLINE-SS PLUG CABLE ASS’Y (20380-#**T-##)
Number of pins : 50P, 40P, 35P, 32P, 30P, 20P,14P,10P
Cable : MICRO-COAX CABLE AWG#40,42 (See Table.1 for jacket diameter)
Each simulation is connected to all Pins.
Bonding : CABLINE-SS recommend bonding cable outlets.
When bonding, be sure to bend the cable from the end of the bonding.
Table.1 Cable jacket(outer) diameter (mm)
AWG#
Impedance matching
45ohm 50ohm
40 0.33 0.37
42 0.29 0.33
With Bonding Without Bonding