1 / 16
Document No.
TR
-
13011
-
0
6
EN
Confidential
C
I
-
PEX Inc.
QKE-DFFDE07-07 REV.10
MHF
Ā®
4L Connector
Part No. Plug: 20565-001R-13, 20572-001R-08 / Receptacle: 20449-001E-**
Test Report
Product Specification no. PRS-1772
6 T21032 May 19, 2021 N. Miyashiro K. Ikeshita M. Takemoto
5 T20085 October 23, 2020 J.Tonai M. Takemoto
4 T20055 August 5, 2020 K. Ikeshita J. Tonai M. Takemoto
3 T18126 November 6, 2018
M.Nomoto K.Yufu K.Yotsutani
Rev. ECN Date Prepared by Checked by Approved by
MHF 4L Connector
Test Report
Document No.
TR
-
13011
-
0
6
EN
2 / 16
Confidential
C
1. Purpose
To evaluate the performance of MHF 4L Connector in accordance with PRS-1772.
2. Specimen
(1) MHF 4L PLUG (Part No: 20565-001R-13)
Cable : AWG#32 coaxial cable (Jacket diameter 1.13mm)
(2) MHF 4L PLUG (Part No: 20572-001R-08)
Cable : AWG#36 coaxial cable (Jacket diameter 0.81mm)
(3) MHF 4 RECEPTACLE (Part No. 20449-001E-**)
3ļ¼ŽTest Sequence
All the evaluations were performed in accordance with Table 1 Test Sequence.
4. Result
See Table 2, and graphs following Graph 1. For the details of the testing conditions and requirements, see
PRS-1772. The ā€œnā€ in the tables show the number of measurement points.
5. Conclusion
All the specimens met the requirements of PRS-1772.