1 / 9
Document No.PRS-1239-18EN
Confidential
C
I
PEX Inc.
QKE-DFFDE06-08 REV.12
CABLINE
®
-SS Connector
Part No. Plug: 20380-***T-**, Receptacle: 20374-***E-**-*
Product Specification
Qualification Test Report No. TR-04037
18 S22097 March 8, 2022 E.Tanaka K.Hara H.Ikari
17 S21627 November 24, 2021
R.Hatano T.Tanigawa H.Ikari
16 S19375 June 11, 2019 K.Hara T.Masunaga H.Ikari
15 S18454 July 20, 2018 H.Aoki Y.Shimada
Rev. ECN Date Prepared by Checked by Approved by
CABLINE
-
SS
Product Specification
Document No.
PRS
-
1239
-
1
8
EN
2 / 9
Confidential
C
1. Scope
This Product Specification defines the test conditions and the performances of the CABLINE-SS Connector, a wire-to-board connector of
0.4 mm contact pitch.
2. Product Name and Parts No.
2.1 Product Name
CABLINE-SS
2.2 Parts No.
1 CABLINE-SS PLUG FOR CABLE ASS’Y (Part No. 20380-***T-**)
CABLINE-SS PLUG HOUSING ASS’Y (Part No. 20373-***T-0*-*)
CABLINE-SS METAL COVER (Part No. 2182-0**-0**)
2 CABLINE-SS RECEPTACLE ASS’Y (Part No. 20374-***E-**-*)
3. Rating
3.1 Applicable Cable
AWG#42, #40, #36, #34
3.2 Operating Conditions
Amperage: 0.24A AC/DC [AWG#42]apply to all pins
0.25A AC/DC [AWG#40]apply to all pins
0.30A AC/DC [AWG#40]maximum 32pins. / for POWER
0.35A AC/DC [AWG#36]apply to all pins
0.40A AC/DC [AWG#36]maximum 37pins. / for POWER
0.35A AC/DC [AWG#34]apply to all pins
1.00A AC/DC [AWG#34]maximum 2 pins. / for POWER
AWG#36: Micro-Coax cable and Discrete cable
AWG#34: Discrete cable only
Contact us before applying amperage other than the above.
Voltage: 100V AC (per contact pin)
Operating temperature: 233358K(-4085)
(Containing temperature rise by current)
Operating humidity: 85% max (Non-condensing)
3.3 Storage Conditions
Storage temperature: 248333K(-2560)
Storage humidity: 85% max. (Non-condensing)
Storage period:
Before opening ・・・ 1 year after product is delivered.
After opening, use it as soon as possible.
4. Test and Performance
Test Condition
This initial test is equal to it’s at shipping condition and unless otherwise specified, all tests and measurements shall be performed under
the following conditions in accordance with MIL-STD-202.
Temperature… 288 K308 K15 35
Pressure… 866 hPa1066 hPa650 mmHg800 mmHg
Relative humidity… 4575 %R.H.