The compact OEM pressure transmitter
programme is designed for use in severe
hydraulic applications. The programme consists
of two series:
MBS 1600 – without integrated pulse-snubber
MBS 1650 – with integrated pulse-snubber
The integrated pulse-snubber offers a high
degree of protection against cavitations and
liquid hammer, and the well thought out design
results in excellent vibration stability and an
exceptional robustness. The high degree of EMI
protection equips the pressure transmitter to
meet most requirements.
Features Designed for use in severe OEM applications
For medium and ambient temperatures
up to 125 °C
All standard output signals:
4 – 20 mA, 1 – 5 V, 1 – 6 V, 0 – 10 V
Wetted parts made of stainless steel
Immunity to electrical noise from VFD
Immunity to direct coupled transients
Immunity to pulse magnetic field
Mis-wire protected
Short circuit protected
A wide range of pressure and electrical
connections
EMC protection up to 100 V/m
MTTFd > 100 years
Data sheet
OEM Pressure transmitters for heavy-duty applications
MBS 1600 and MBS 1650
© Danfoss | DCS (im) | 2020.05
Data sheet | OEM transmitters for heavy-duty applications, MBS 1600 and MBS 1650
2 | AI204986442305en-000201 | 520B7558
Technical data
Accuracy (incl. nonlinearity, hysteresis and repeatability) ± 0.5% FS
Thermal zero point shift <± 0.15% FS / 10K
Thermal span shift <± 0.15% FS / 10K
Response time liquids (10 – 90%) ~ 1 ms
1
)
Durability, P: 10 – 90% FS >10 × 10
6
cycles
1
) Further details please contact Danfoss
Performance (EN 60770)
Nominal pressure [bar] 6 10 16 25 40 60 100 160 250 400 500 600
1000
2
) 1600
2
) 2200
2
)
Overload pressure 21 30 48 80 80 140 200 320 500 800 1400 1400 2000 2500 3000
Burst pressure 280 400 640 800 800 1400 2000 1600 2500 4000 >4000 >4000 >4000 >4000 >4000
2
) Only available with M12 × 1 1.5 P high pressure port, type FC06. Please contact Danfoss.
Overload and burst pressure – without pulse-snubber (MBS 1600)
Nominal pressure [bar] 6 10 16 25 40 60 100 160 250 400 500 600
Overload pressure 21 30 48 120 120 210 300 480 750 1200 2100 2100
Burst pressure 280 400 640 800 800 1400 2000 1600 2500 4000 >4000 >4000
Overload and burst pressure – with integrated pulse-snubber (MBS 1650)
Electrical specifications
Nom. output signal
(Short-circuit protected)
4 – 20 mA
(2 wire)
0 – 5 V, 1 – 5 V
1 – 6 V
0 – 10 V
Supply voltage [U
B
], polarity protected 8 – 32 V 8 – 32 V 12 – 32 V
Supply – current consumption 4.5 mA 4.5 mA
Output impedance ≤ 90 Ω ≤ 90 Ω
Load [R
L
] (connected to 0 V ) See chart below R
L
≥ 10 kΩ R
L
≥ 10 kΩ
Load [R
L
] (connected to + V ) See chart below Not possible Not possible
Note:
Loop current should not
exceed 22 mA continuous or
25 mA temporarily due to
pressure peaks
4 – 20 mA output - min. / max. resistance vs. supply voltage
Pulse-snubber in MBS 1650 Application
Cavitation, liquid hammer and pressure peaks
may occur in liquid filled systems with changes
in flow velocity, e.g. fast closing of a valve
or pump starts and stops.
The problem may occur on the inlet and outlet
side, even at rather low operating pressures.
The media viscosity has only little effect on the
response time. Even at viscosities up to 100 cSt,
the response time will not exceed 4 ms.