Revision 5/29/2018
WWW.PHIHONG.COM
75W Power over Ethernet Adapter
Ultra Power over Ethernet Single Port Injector
Shown here in standard on the left and with NIC option on the right
Features
Gigabit Compatible
Full Protection OCP, OVP
Diagnostic LEDs
Limited Power Source
Single Source 4 Pair Power Current
Sharing
Full Power Cisco AP1250 Support
Not IEEE BT Compliant
SNMP Management Option
Broken Wire Detection
1 Year Warranty
12.5k or 25k on Datapairs 3, 6, 1, 2 for
Detection(Latest Revision)
Applications
Satellite Receiver
Security Cameras
Wireless Network Access Points
Kiosks
LCD Displays
Computer Workstations
Safety Approvals
cUL/UL
CE
Mechanical Characteristics (Standard Model)
Length: 166mm (6.53in)
Height: 44mm (1.73in)
Width: 80mm (3.15in)
Weight: 0.5Kg
Output Specifications
Notes:
1. 4-pair powering for 2 outputs at 56V, 0.67A
2. Consult factory for availability
Reference files:
1. SNMPv2c_User_Manual-Rev1.7.pdf
2. SNMPv2c_Firmware-Rev1.7.zip
3. SNMPv2c_MIB_10_30_2009.zip
Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for
the most up-to-date specifications and contact information.
Model
DC Output
Voltage*
Load x2
4-pair powering
1
Regulation
POE75U-1UP-N
2
+56V
Max.
Line
Load
0.67A
54-57V DC under all conditions
Revision 5/29/2018
POE75U-1UP-N Characteristics
WWW.PHIHONG.COM
INPUT:
AC Input Voltage Range
90 to 264VAC
AC Input Voltage Rating
100 to 240VAC, 47-63Hz
AC Input Current
2.0A (RMS) max for 90VAC
1.2A (RMS) max for 240VAC
Leakage Current
3.5mA max @ 254VAC 60Hz
AC Inrush Current
30A (RMS) max for 115VAC
60A (RMS) max for 230VAC
OUTPUT:
Total Output Power
75W
Ripple and Regulation
250mV max
DC Offset
No data degradation with DC imbalance
18mA per min.
Efficiency
80% (typical) at max load, 120VAC 60Hz
Hold-up Time
10mS min. 120VAC and max load
Transient O/P Voltage Protection
60V max
ENVIRONMENTAL:
Temperature
Operation -20 to +40°C
Non-operation -25 to +65°C
Humidity 5 to 90%
EMC
Complies with FCC Class B
Complies with EN55032 Class B
Isolation Test
Primary to Secondary: 4242VDC for 1 minute
10mA
Primary to Field Ground: 2121VDC for 1
minute
Output to Field Ground: 2121VDC
Immunity
ESD: EN61000-4-2. Level 3
RS: EN61000-4-3. Level 3
EFT: EN61000-4-4. Level 2
Surge: EN61000-4-5. Level 3
CS: EN61000-4-6. Level 2
Voltage Dips EN61000-4-11
Harmonic: EN61000-3-2 Class A
Insulation Resistance
Primary to Secondary: >10M OHM
500VDC
Primary to Field Ground: >10M OHM
500VDC
IEEE 802.3af/at Interoperability
If 25kohm or 12.5Kohm is detected the unit
operates in 4-pair powering mode delivering
75W.
FEATURES:
Cisco Legacy detection
No external parts required for Legacy
devices:
VoIP Phones: 7910,7912,7940,7960
Access Points: 350,1100,1200,1250
Over Voltage/Current, Short Circuit
Protection
Outputs equipped with short circuit
protection and overload protection as per
802.3af specifications except max average
current is 1.34A. The output can be shorted
permanently without damage.