INPUT:
AC Input Voltage Rating
100 to 240VAC
AC Input Voltage Range
90 to 264VAC
AC Input Current
0.28A (RMS) maximum at 115VAC input
0.16A (RMS) maximum at 230VAC input
Leakage Current
20μA maximum @254Vac/50Hz
Inrush Current (cold)
<60A for 240VAC at max. load
(Cold start @ ambient 25°C)
Input Power Saving
≦30mW @no load at 230Vac/50Hz
OUTPUT:
Power
10W Continuous
Efficiency
DOE Level VI
Hold-up Time
6mS minimum at 115Vac/60Hz
Emissions
Complies with FCC Class B
Complies with EN55022 Class B
ENVIRONMENTAL:
Temperature
Operation 0°C to +40°C
Non-operation -20°C to +70°C
Humidity 90%
Immunity
ESD: EN61000-4-2 Level 4
RS: EN61000-4-3 Level 2
EFT: EN61000-4-4 Level 2
Surge: EN61000-4-5 Level 3
Dip: EN61000-4-11Level 3
Harmonic: EN61000-3-2
Flicker: EN61000-3-3
Dielectric Withstand (Hi-pot) Test
Primary to Secondary: 3000VAC, 10mA, for
1min
Insulation Resistance
Primary to Secondary: >10M ohm 500VDC
FEATURES
Over-voltage Protection
Output voltage shall not exceed 8V
Over-current Protection
Output current shall not exceed 3A
Short Circuit Protection
Auto recovery and no component damage
DC Output Connector
USB A