www.netmodule.com Switzerland +41 31 985 25 10
sales@netmodule.com Germany +49 6196 77 99 79 0
NetModule AG Maulbeerstrasse 10
Switzerland 3011 Bern
NetModule GmbH Frankfurter Str. 10-14
Germany 65760 Eschborn
16.04.2022, ©NetModule AG, Product Information NB1601-Gr, Errors reserved 1
NB1601-Gr
Industrial Router with GSM-R + 4x ETH
Modular mobile router with 4-port Ethernet switch to connect remote locations.
Keyfeatures
Mobile / Cellular 1x GSM-R
SIM 2x Micro SIM
Ethernet 4x Fast Ethernet
IO 2x Digital I/O
Operation
Temperature
-40°C to +70 °C
Serial / Fieldbus 1x RS-232 Console
Software Routing, Network Services, VPN, Firewall, Link Management, Supervisor,
SDK, free updates
Compliance CE (RED)
Customizable Extensions on request
Product description
The NB1601 offers the key technologies for stationary applications that require reliable
Internet access.
Applications
• Fleet Management
• Ticketing
• Telematics
• Smart Traffic
Specifications
Mobile / Cellular
Standard
1x GSM-R for EMEA
4G – LTE n.a.
3G - DC-HSPA+/UMTS n.a.
2G - GSM/GPRS GSM-R (876-880 / 921-925), B8 (900), B3 (1800)
Category GPRS Multislot class 10
Output Power GSM-R Power Class 4 (2W)
Antenna ports SISO
Data rate down / up (max) 85.6 kbps / 42.8 kbps
Voice GSM (HR/FR/EFR/AMR)
ASCI n.a.
Region
Europe, Middle East and Africa (EMEA)
Connectors
1x SMA female
SIM
2x Micro SIM - 3FF
Ethernet
Standard
4x Fast Ethernet
Ethernet standard 100BASE-TX, Auto MDIX
Speed 10/100 Mbps
Connector
4x RJ45
USB
Standard
1x USB 2.0 Host
Connector
1x Type A
Serial, Fieldbus
Protocol
1x RS-232
Protocol EIA-232
Signals TX, RX
Signal level High > 5 VDC, low < -5 VDC
Bit rate Up to 1 Mbps
Connector
1x Terminal block header 3.5 mm (screw locking)
2
IOs
Type
2x Digital I/O
Signals 1x DI, 1x DO
DI signals +, -
DI level Low: 0 - 3 VDC, high: 9 - 32 VDC
DO signals Relay outputs with NO, NC, COM (normally open, normally closed)
DO level 0 - 32 VDC/1A
Isolation 1'500 VDC
Connector
1x Terminal block header 3.5 mm (screw locking)
System
Core
600 MHz (HW Rev. A) or 1 GHz (HW Rev. B02) single core, 512 MB RAM, 4 GB flash
Module Slots
1x miniPCIe / extension combo (USB), 1x Shield
Software
Features
NetModule Router Software
Package The standard software package includes an intuitive user interface, covering all modern routing protocols and enables
efficient mass deployment.
General Fail-safe update (FOTA), upgrade via USB, HTTP(S), (S)FTP or TFTP, remote CLI & WebGUI, RADIUS authentication,
Simple Certificate Enrollment Protocol (SCEP), logging
Remote Management Manage and monitor devices with SNMP, telnet, SSH, or HTTP/HTTPS
Cellular Networking Multi-SIM / soft-SIM support, multi-APN support, signal strength monitoring, dedicated bearers, GSM/CSFB
calls
Wireless LAN Client or Access Point mode, multi client support, multi / hidden SSID, WPA-PSK/WPA2-PSK, WPA-RADIUS, WPA-
EAP-TLS, IEEE 802.11w, RADIUS accounting, CAPWAP
Link Management Link prioritisation, link aggregation, load balancing, multipath-TCP, IP-passthrough, link supervision
Network Services DHCP Client, DNS server, email, SMS service, NTP Client, NTP server, DynDNS, SSH server, SNMP agent,
HTTP/HTTPS/FTP server, voice gateway, SIP call routing, coovachilli hotspot
Routing Destination, policy, multipath, mobile-IP, OSPF, BGP, TCP-MSS clamping, STP/RSTP, bridging, LLDP, CDP, SONMP, EDP,
FDP, IRDP, VRRP, VLAN, PPPoE
VPN OpenVPN, IPsec, PPTP, GRE, CSD dial-in
Firewall Stateful firewall, connection tracking, NAPT, masquerading, bridge filtering
Power
Input Voltage
12, 24 VDC
Nominal voltages 12, 24 VDC
Absolute voltages 12 VDC to 24 VDC (-20 % / +20 %)
Connector
1x Terminal block header 3.5 mm (screw locking)
Consumption
5 W (average), 7 W (max)
Mounting
DIN-Rail
Dimensions
W x H x D
Width 45 mm x height 124/134 mm x depth 110/121 mm
Weight
450 g
Environment
Operating
Temperature
-40°C to +55°C
Ingress Protection
Level
IP40
MTBF
300’000 h / 34.2 years, according SN29500 at environmental temperature 40 °C
Certifications
Compliance
CE according to 2014/53/EU (RED), 2011/65/EU (RoHS)
Domain
Industrial
Order Code
NB1601-Gr