Maximum DC Blocking Voltage
Parameter
Maximum Repetitive Peak Reverse Voltage
Maximum RMS voltage
Maximum Average Forward Rectified Current
20
40
V
14
28
V
V
3.0
0.5
5
-55 ~ +125
A
A
V
mA
°C
Units
20 40
Peak Forward Surge Current,8.3ms
Single Half Sine-wave Superimposed
on Rated Load (JEDEC method)
Max Instantaneous Forward Voltage at 3 A
Maximum DC Reverse Current
at Rated DC Reverse Voltage
Operating Junction Temperature Range
SS
32
T
a
= 25°C
T
a
=100°C
V
RRM
V
RMS
V
DC
I
F(AV)
I
FSM
V
F
I
R
T
j
Symbol
T
stg
Storage Temperature Range
60
42
60
80
56
80
100
100
0.55 0.70 0.85
-55 ~ +150
°C
120
120
150
105
150
200
140
200
0.95
0.3
3
80
70 84
45
31.5
45
70
Typical Thermal Resistance
°C/W
R
θJA
pF
C
j
450 400
Typical Junction Capacitance
(1)
(2)
Measured at 1 MHz and applied reverse voltage of 4 V D.C
(2)
(1)
P.C.B. mounted with 2.0" X 2.0" (5 X 5 cm) copper pad areas.
SS32 Series
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 °C ambient temperature unless otherwise specified. Single phase half-
wave 60 Hz, resistive or inductive load, for capacitive load current derate by 20 %.
SS
34
SS
34A
SS
36
SS
38
SS
310
SS
312
SS
315
SS
320