WIRELESS SAFETY
PERIMETER
Position several Honeywell BW
RigRat monitors to form a wireless
safety perimeter.
REMOTE MONITORING
Use with Honeywell’s remote
monitoring software to see gas
readings, location and other data
from any device with an internet
connection — for fast, informed
decisions. Add an optional noise
sensor or meteorological sensor.
HONEYWELL
TOUCHPOINT™ PLUS
COMPATIBLE
Use with the Honeywell
Touchpoint™ Plus controller for visibility
on Honeywell BW™ RigRat monitors
and workers’ personal detectors.
FEATURES AND BENEFITS
Honeywell BW™ RigRat is so easy to use that workers can operate it with confidence,
trusting it to alert them to gas threats in their proximity — indoors and out, in
temperatures from 40 to +140°F (40 to +60°C). Honeywell BW™ RigRat delivers:
Up to 8 weeks of runtime on a single
charge. Longer runtime than any area
monitor in its class.
Up to six slots for interchangeable
gas sensors. Choice of
electrochemical, PID, infrared, and
catalytic bead sensors (measuring
percent LEL and percent by volume).
Integrated Noise sensor and
Metrological data sensors.
Enhanced configurations with
programmable input and output.
Approval for explosive atmosphere.
Certified for ATEX/IECEx Zone 0 and
CSA C1D1.
Flexible applications. Zone
declassification, turnarounds, confined
space, routine maintenance, fence
line and more. Available with pump for
remote sampling.
One-button operation. Grab and go.
No expertise required.
Simple setup with a smartphone.
Easy mobile app for alarm set points,
calibration records and more.
Added protection. Alerts workers to
nearby gas leaks, whereas personal
detectors cover only the breathing
zone.
Transportable Multi-gas Area Monitor
HONEYWELL BW RIGRAT
Comply with safety procedures and protect
workers with the most user-friendly area
monitor of its kind.
OTHER HONEYWELL BW
TM
RIGRAT FEATURES:
Line power for extended runtime in
the field
I/O ports providing additional input
capabilities and local executive
activation.
Inert mode that prevents alarm in
normal ambient air.
Large, easy-to-read display
Rugged, weatherproof design, with
optional protective cage
HONEYWELL BW™ RIGRAT TECHNICAL SPECIFICATIONS
INSTRUMENT SPECIFICATIONS (TYPICAL)
MODEL NUMBER BWRR100P/BWRR100D
SIZE 15.8 x 11.4 x 18.5 in. / 40.0 x 29.0 x 47.0 cm
WEIGHT 17.6 lb / 8 kg
GAS SENSOR SLOTS Up to 6
GAS SAMPLING METHOD Pumped or diffusion
BATTERY Rechargeable Li-ion battery (3.7V / 26.4 Ah)
CHARGING TIME Less than 18 hours when instrument is powered off
RUNNING TIME 8 weeks for low-power model; other models vary by configuration
KEYPADS One-button operation and programing
DISPLAY 3.5” 240 x 320 TFT color LCD with white LED backlight
ALARM Red/yellow/green LED alarm; buzzer alarm 108 dBA @ 1 m; on-screen indication of alarm conditions
DATALOGGING Complete gas sensors and instrument information for at least 4 months at one minute intervals
WIRELESS
ISM license free band:
Bluetooth Low Energy Module (BT 4.2 / 5.0), 2.4 GHz, in default;
Mesh Module: IEEE 802.15.4 868 MHz / 915MHz /2.4 GHz (optional); OR
WiFi Module: 802.11 b/g/n 2.4 GHz (optional)
RADIO MODULE & RANGE
Bluetooth Low Energy: RMBLEC, up to 16.4 ft. / 5 m;
Mesh: RM900A, 984 ft. / 300 m (868-900 MHz) or RM2400, 492 ft. / 150 m (2.4 GHz );
WiFi: RMWIFIC, up to 164 ft. / 50 m;
OUTDOOR LOCATION
GPS receiver module: GPS L1 frequency (1575.42 MHz) (optional);
Only with IEEE 802.15.4 868 MHz / 915MHz modem and WIFI
IP RATING IP65 for pumped models; IP67 for diffusion models
TEMPERATURE
4 to +140°F (20 to +60°C) for pumped models;
40 to +140°F (40 to +60°C) for diffusion models
HUMIDITY
5 - 95% RH (non-condensing)
SAFETY CERTIFICATIONS
(PENDING)
cETLus Class I Division 1; Group A, B, C, D; T4;
IEC EX/ATEX
I M1 Ex ia I Ma
II 1G Ex ia da IIC T4 Ga
For LELIR/CO
2
sensor installed:
I M1 Ex ia I Ma
II 2G Ex ia da db IIC T4 Gb
1G Ex ia da IIC T4 Ga
WIRELESS APPROVALS
(PENDING)
FCC Part 15, IC, RED
ROHS (PENDING) RoHS Complaint, Directive (EU) 2015/863
NOISE SENOR
60125 dBA range; (respond: 100 Hz to 8 kHz), 1 dB resolution;
A-weighted 15 second equivalent level; updated every 5 seconds
EXTERNAL PORTS
SAFE AREA CHARGE PORT
(AC CHG SAFE AREA)
Battery charger input 6 VDC 3 A typical; connect to AC/DC adaptor
FIELD CHARGE
(IS CHG HAZARDOUS)
Intrinsically safe line power supply input to extend instrument runtime (low-power model only)
RAEMET PORT (SERIAL) Port to RAEMet wind sensor (optional)
ANALOG/SWITCH INPUT PORT
(420 MA IN)
420 mA signal input, X1 channel/switch on/off signal input, X1 channel (optional)
ON/OFF SWITCH OUTPUT
(SWITCH)
Max 20 V / 120 mA, SPDT Normal Open, X3 channels for external ports (optional). Refer to User Guide for
complete details.