© 2016, AFL, all rights reserved. PP-2-00241, Revision 11, 7.31.20
Specications are subject to change without notice.
AFLglobal.com
|
800.235.3423
181
Optical Connectivity
Fiber Management
AFL TRIDENT factory-terminated drop cables are the nal piece of the AFL TITAN RTD
®
FTTx
System. The quarter-turn latching and sealing mechanism of the AFL TRIDENT connector provides
quick and easy “plug and play” connections to AFL TITAN RTD multiport terminals, enabling
lighting fast service subscriber connections with outstanding long term reliability. The connector/
adapter interface is keyed to ensure proper alignment of the 2.5 mm APC ferrule. Once the
connector is keyed and inserted, locking and sealing is provided with a “BNC-like” quarter-turn
of the connector coupling. Drops are available with one or both ends terminated (either both
ends AFL TRIDENT or hybrid—one end AFL TRIDENT and one end standard SC). Drop cables are
available in one, two, or four bers (at drop only).
AFL TRIDENT
®
Hardened Drop Cables
Features
AFL TRIDENT Hardened Connector ports for speedy customer connections
Factory terminated on:
- 250 μm outdoor or 900 μm indoor/outdoor at drop cable
- 250 μm armored drop
- 900 μm pushable/air-jettable MicroDrop
Flat drop is aerial self-support capable
Cable Components
Dielectric OSP
UV Resistant Jacket
Water Blocking Dielectric
Strength Member
Water Blocking Dielectric
Strength Member
Water Blocking Thread
Optical Fiber
Gel-Filled Loose
Buffer Tube
Toneable Indoor/Outdoor
UV Resistant Jacket
Water Blocking Dielectric
Strength Member
Water Blocking Dielectric
Strength Member
Toneable Copper Element
Water Blocking Thread
900 μm Tight Buffered
Optical Fiber
OFNR Jacket
Aramid Yarns
Armored Drop
UV Resistant Jacket
Corrugated Steel Armor
Rip Cords
Dielectric Water Blocking
Strength Members
Optical Fiber
PFM
Gel-Filled Tube
MicroDrop
Tight Buffer Tube
Outer Sheath
Water Blocking
Aramid Yarns
Optical Fiber
Strength Member
Qualifications
GOVERNING BODY STANDARD CODE
Telcordia GR-3120
© 2016, AFL, all rights reserved. PP-2-00241, Revision 11, 7.31.20
Specications are subject to change without notice.
AFLglobal.com
|
800.235.3423
182
Optical Connectivity
Fiber Management
AFL TRIDENT
®
Hardened Drop Cables
AFL TRIDENT Hardened Connector Specifications
PARAMETER VALUE
Insertion Loss, Maximum 0.50 dB
Insertion Loss, Typical 0.15 dB
Reection ≤ -65 dB
Operating Temperature -40°C to +75°C
Retention Force 25 lbs (111 N)
Dust Cap Pulling Eye Tension 100 lbs (444 N)*
Cable Specifications (Flat Drop Cable Only)
Max Span Length at 1% Sag
NESC Light 550 ft (168 m)
NESC Medium 275 ft (84 m)
NESC Heavy 150 ft (46 m)
Ordering Information
Inside End Connector
XXX = No connector
TASC = Trident
ASC = Angle SC
XXX
Fiber Type
Q = Single-mode
ITU-T G.652.D
Z = Single-mode
ITU-T G.657.A2 BIF
(for I/O at drop)
Q
Cable Length
*4 digits
Example: 0100F
for 100 feet
0100TD
Cable Type
DD = Dielectric Flat Drop
TD = Toneable Flat Drop
KTD = Toneable Indoor/Outdoor
Flat Drop
KDD = Dielectric Indoor/Outdoor
Flat Drop
AN = Armored Drop
PD = Pushable MicroDrop
001
Fiber Count
001
002
004
UOM
F = Feet
M = Meter
FTASC
Outside End Connector
XXX = No connector
TASC = Trident
ASC = Angle SC