Sheet 2 of 4
No. Item Specification
11 Humidity temperature
cycling
When tested in accordance with method 106 of MIL-STD-202F, there
shall be no physical damage to the connectors. After the test, the
insulation resistance shall be no less than 100 MΩ. The contact
resistance shall not exceed 180 mΩ as well.
Humidity: 80% to 98%
Number of cycles: 10
12 Thermal Shock When tested in accordance with JIS C 5402 7.2, ( 5 cycles in the
environment shown in below program), there shall be no physical
damage to the connectors. After the test, the contact resistance shall
not exceed 180 mΩ.
13 Vibration
When tested in accordance with method 201 of MIL-STD-202F, Test
condition A (Frequency: 10 Hz to 55Hz, Acceleration: 147 m/s
2
peak,
Magnitude: 1.52 mm), there shall be no physical damage to the
connectors. During the test, there shall be no electrical discontinuity
of the test circuit greater than 1 microsecond.
(100 mA DC of current is applied to the circuit.)
After the test, the contact resistance shall not exceed 180 mΩ.
14 Physical Shock
When tested in accordance with method 213 of MIL-STD-202F, Test
condition A (Semi-sine wave, Acceleration: 490 m/s
2
, Standard holding
time: 6 msec.), there shall be no physical damage to the connectors.
During the test, there shall be no electrical discontinuity of the test
circuit greater than 1 microsecond.
(100 mA DC of current is applied to the circuit.)
After the test, the contact resistance shall not exceed 180 mΩ.
-40 degrees C
+25 degrees C
+85 degrees C
30 min 30 min
5 min 5 min
1 Cycle
24 hour
1 cycle
+65°C
+25°C
-10°C