© 2016, AFL, all rights reserved. PP-2-00240, Revision 7, 7.31.20
Specications are subject to change without notice.
AFLglobal.com
|
800.235.3423
179
Optical Connectivity
The AFL TITAN RTD Multiport is a factory terminated OSP ber terminal designed for quick
and easy subscriber connections anywhere in the OSP network when used in conjunction
with AFL TRIDENT
®
Hardened Fiber Optic Connectors. The sealed and rugged design of both
the AFL TITAN RTD Multiport and AFL TRIDENT connector allow for long term reliability when
installed anywhere in the network—underground, in pedestals, on poles, or on aerial strand
or ADSS cables.
The preterminated AFL TITAN RTD Multiport Terminal is available with a variety of
cable stub options. Dielectric or toneable at drop cables are available for underground or
short span self-support applications while ADSS cable stubs are available for longer span
self-support applications*. Round armored cables are available for rodent protection in aerial
or direct buried applications. Lastly, a pushable/air-jettable MicroDrop cable is available for
microduct jetting applications.
The multiple stub options allow for exibility when engineering the network and
consolidation of multiple terminal stubs into one centralized splice point. The terminal is
outtted with four, six, eight or twelve AFL TRIDENT connector ports. The AFL TITAN RTD
Multiport and AFL TRIDENT Hardened Fiber Optic Connector are designed and tested to
Telcordia GR-771 and Telcordia GR-3120, respectively.
Lengths less than 350 feet ship coiled in low-prole boxes. Lengths more than 350 feet ship
on a 33" corrugated plastic reel inside a cardboard box.
*Refer to "AFL TITAN/TRIDENT Sag and Tension Guide" Applications Engineering Note for guidance on allowable span lengths for various stub options
AFL TITAN RTD
®
FTTx System
Features
• AFL TRIDENT Hardened Connector ports
for speedy customer connections
• Stubbed with a large variety of cable
options including at drop*, ADSS*,
pushable/air-jettable MicroDrop, or
armored drop.
• Factory sealed for deployment in up to 10
feet of water head, but re-enterable for
connector repair
• Pole and swing arm mountable;
aerial mounting bracket available
for strand mount
• Low prole design—4 and 6 port
t into 6" pedestals
Multiport Terminal Specifications
PARAMETER VALUE
Dimensions (L x W x H)
4- and 6-port
12.4" x 4.9 " x 3.0"
315 mm x 125 mm x 76 mm
8- and 12-port
15.5" x 6.1" x 3.8"
394 mm x 195 mm x 96 mm
Weight
4- and 6-port 1.5 lb (0.7 kg)
8- and 12-port 2.5 lb (1.1 kg)
AFL TRIDENT Hardened Connector Specifications
PARAMETER VALUE
Insertion Loss, Maximum 0.50 dB
Insertion Loss, Typical 0.15 dB
Reection ≤ -65 dB
Operating Temperature -40°C to +75°C
AFL TITAN RTD Multiport Terminal
AFL TRIDENT Hardened Connector
Fiber Management
Qualifications
GOVERNING BODY STANDARD CODE
Telcordia GR-771, GR-3120