Viewing and Configuring End Devices
Once an End Device is connected to the ZW-REC it
is visible in the End Device Readings Page:
By default, End Devices are sorted by Device ID and
up to 10 End Devices are shown. Use the
Previous
and
Next
buttons to show additional pages of End
Devices.
The refresh rate of the web page is shown in the
bottom left. This is how often the web page refreshes
the displayed data. This number does not reflect how
often the End Device takes readings.
Connected End Devices
and Sensors can be
configured by clicking
the settings icon in
the right column. Here
you can give the End
Device a name, change
the update interval and
add offsets to sensor
readings.
The update interval is
the frequency End
Devices transmit
readings. By default,
most End Devices send
one reading every 10
seconds. The update
interval greatly effects
the battery life of End Devices. The shorter the
update interval the shorter the battery life will be.
After making changes use the
Update
button to save
the settings.
ZW-REC Configuration
Once the ZW-REC is communicating with the End
Devices, finish configuration of the ZW-REC.
Click on the System tab in the upper right to bring up
ZW-REC System Settings. Login to the page using
the Administrator credentials shown in
Step 3.
The System information is shown at the top of the
page including firmware revision and PAN ID. Use
the PAN ID to configure UW Series devices. Click the
information icon for help with setting up zSeries and
zwSeries End Devices.
When the ZW-REC starts up, it performs an energy
scan to find a clear RF channel. This RF channel is
displayed in the Radio Section. To prevent the ZW-
REC from re-scanning when it is rebooted uncheck
the Enable Energy Scan box and press
Save
. This
allows End
Devices to
automatically
reconnect to
the ZW-REC
after a
reboot.
The Measurement Units section selects between SI
and Imperial units for temperature and pressure.
Select the desired units and press
Save
. End
Devices
with LCDs
will reflect
the new
settings
after they
next
transmit.
Other Features
The ZW-REC has many additional features to help
visualize your data and to integrate with your
network. You can change the IP Address to connect
to a different sub-net. The ZW-REC also integrates
with DHCP and DNS servers and full HTTPS
encryption is available.
An integrated chart page allows for local data
visualization and chart data can be saved to your
local computer. The ZW-REC also works with the
Omega Dashboard for comprehensive data logging,
charting and e-mail alarm notification.
For more information, please refer to the full user
manual.
Note: To view Wireless Certification Statement
please view full product manual at,
www.omega.com/manuals/manualpdf/M5546.pdf
5
6
7
ZW-REC
zwSeries Wireless Receiver
MQS5546/0618
omega.com info@omega.com
TM
The information contained in this document is believed to be correct, but
OMEGA accepts no liability for any errors it contains, and reserves the right to
alter specifications without notice.
Servicing North America:
U.S.A. Omega Engineering, Inc.
Headquarters: Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only)
Engineering Service: 1-800-872-9436 (USA & Canada only)
Tel: (203) 359-1660 Fax: (203) 359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
For complete product manual:
www.omega.com/manuals/manualpdf/M5546.pdf
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period
of 25 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to
the normal two
(2) year product warranty to cover handling and shipping time. This ensures that OMEGA’s
customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory
for evalua-tion. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately
upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it
will be
repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the
purchaser, includ-ing but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modifica-tion. This WARRANTY is VOID if the unit shows evidence of having
been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat,
moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of
OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses,
and triacs.
OMEGA is pleased to offer suggestions on the use of its vari-ous products. However, OMEGA neither
assumes responsibil-ity for any omissions or errors nor assumes liability for any damages that result
from the use if its products in accordance with information provided by OMEGA, either verbal or writ-
ten. OMEGA warrants only that the parts manufactured by the company will be as specified and free
of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND
WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES
INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set
forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based
on contract, warran-ty, negligence, indemnification, strict liability or otherwise, shall not exceed the
purchase price of the component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component”
under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical appli-cations or used on
humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on
humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/
DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any
liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO
AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
FOR WARRANTY RETURNS, please have the
following information available BEFORE contacting
OMEGA:
1. Purchase Order number under which the product
was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative
OMEGA’s policy
is to make running changes, not model changes, whenever an improvement is possible.
This affords our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied,
photocopied, reproduced,
translated, or reduced to any electronic medium or machine-readable form, in whole or
in part, without the prior written consent of OMEGA ENGINEERING, INC.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for
current repair charges. Have the following information
available BEFORE contacting OMEGA:
Purchase Order number to cover the COST of the
repair or calibration,
Model and serial number of the product, and
Repair instructions and/or specific problems relative to
the product.
1.
2.
3.
Singapore
Using This Quick Start Manual
Use this Quick Start Manual to set up your zwSeries
wireless system and begin operation. Information is
provided on:
Required equipment
Configuring your computer
Setting up the ZW-REC
Setting up an End Device
Viewing and Configuring End Devices
ZW-REC Configuration
Other Features
For complete information on all setup options see the
user manual available at omega.com/manuals.
Before You Begin
Warning:
The following parts of the unit
are ESD sensitive:
The Antenna
Metal connectors for the Antenna, USB Port, and
Power
The ZW-REC is designed to be operated in a clean
and dry environment. Care should be taken to
prevent the device from being exposed to moisture,
toxic chemicals, extreme cold or hot temperature that
are outside the specification listed in the user
manual.
Required Equipment
Before setting up a zwSeries wireless system ensure
you have the following components:
ZW-REC Wireless Receiver
ZW-ED or other compatible Wireless End
Device(s)
Measurement Probe (If required. Some End
Devices have Integrated Sensors)
Computer with a free Ethernet port and HTML5
capable web browser
Ethernet Cable (A crossover cable is required for
computers using older 10/100Base-T Network
Interfaces)
Configuring Your Computer
The ZW-REC is configured with a default static IP
Address of 192.168.1.200. Before connecting to the
ZW-REC, first configure your network adaptor so that
it is on the same sub-net.
For Windows:
Open Network and Sharing Center
Click
Change adaptor settings
Select your Network Adaptor
Click
Change settings of this connection
Select Internet Protocol Version 4
Click
Properties
��
Select Use the following IP address:
Enter 192.168.1.100 as the IP address
Click
Okay
Your computer is now setup to communicate with the
ZW-REC.
Setting up the ZW-REC
Before turning the ZW-REC on, first locate the DIP
switches on the back of the unit. These switches set
the Network ID (NID) which the ZW-REC uses to
identify which End Devices to communicate with. The
NID is set to Zero by default. Most End Devices also
have a default NID of Zero.
If NID Zero is used by an existing wireless
installation, change the NID using switches 5 8. If
older zSeries End Devices are used, do not use
switch 8. For more information on setting the NID
consult the full manual.
Attach the included antenna to the ZW-REC.
Power on the ZW-REC using the supplied AC
adaptor. The blue wireless link LED will flash and
then remain on.
Connect the ZW-REC to your computer using an
Ethernet cable. The Network Link and Activity LEDs
will light up to indicate the ZW-REC recognizes an
Ethernet Connection.
Open a web browser and navigate to:
http://192.168.1.200
A dialog box will appear asking for a user name and
password. Use the default Client login information
found below:
User Account
Login Name
Password
Client
login
12345678
Administrator
admin
00000000
The Administrator information is required later.
Setting up an End Device
A blank End Device Readings page is shown once
you have logged into the ZW-REC webpage. As End
Devices are connected to the ZW-REC they appear
in this page.
To connect an End Device to the ZW-REC, first set
the NID of the End Device to be the same as the ZW-
REC. All zSeries and zwSeries devices ship with the
NID set to Zero.
End Devices require a Device ID (DID) to distinguish
between different devices in the network. Most End
Devices ship with a default DID of Zero. If more than
one End Device is being configured, each End
Device needs a unique DID. Please consult the End
Device User Manual for more information on setting
the DID.
UW Series End Devices use a 5 digit NID
called the PAN ID and refer to the DID as
the Address. To find the PAN ID add 13106
to the NID. If you are using a UW Series End Device
please consult the full ZW-REC and UW user
manuals for information on setting the PAN ID and
DID.
If your End Device requires a probe, connect the
probe before applying power to the device. End
Devices may not connect to the ZW-REC if the probe
is not connected.
Attach the included antenna to the End Device. (If
applicable)
Use the supplied batteries and/or AC adaptor to
power on your End Device.
zwSeries and zSeries End Devices blink
their Blue Link LED while searching for the
ZW-REC. Once connected the LED will
stop blinking and flash briefly after each
transmission.
3
2
4
START HERE