www.glenair.com E-Mail: sales@glenair.com
GLENAIR, INC. 1211 AIR WAY GLENDALE, CA 91201-2497 818-247-6000 FAX 818-500-9912
L
L-34
© 2012 Glenair, Inc. U.S. CAGE Code 06324 Printed in U.S.A.
Test Probes
and Kits
GTK3000
Glenair Fiber Optic Testing Kit
for ARINC 801 Fiber Optic Connection Systems
Basic Part Number
Includes:
Power and Source
Meters (Several
Options)
4 Test Probes
(3 meters long)
Calibration Adapter
Type of Meter
Connection
A = ST Connector
B = FC Connector
C = SC Connector
Fiber Size
(See Table I)
How To Order
GTK3000 - B - A
Table I: Fiber Size
Symbol Fiber Size
A 100/140u
B 62.5/125u
C 50/125u
D 200/300u
E 9.3 Single Mode
F Customer Dened
Fiber optic testing kit for ber optic connection systems
Traditional optical test harnesses are expensive and easily contaminated in normal use. The Glenair ber optic
testing kit utilizes a special probe device in conjunction with our precise-mating test adapter, to provide a
complete solution to optical test and measurement. The GTK-3000 comes with a power meter, source meter,
test probes and a test probe calibration adapter. For accurate results, the test probe calibration adapter will
“zero out” your meters.
The Glenair patented test probe design provides less than 1.0 dB insertion loss, and is used with test probe
adapters and a calibration feedthrough to perform ecient measurements of ber optic cable performance.
The kit accommodates all standard ber sizes and multiple ber optic connection systems
Single channel
connector of
choice
FO4309
FA861
Test Probe Jumper
Optical light
source
Optical power
meter
Test Probes
Calibration Adapter
180-173-2 Keyed
180-154M Non-Keyed
Note:
Replacement calibration adapters and test probe jumpers sold separately.
Test probe connector adapters sold separately
The ber optic test probe kit supports ARINC 801, ber optic connection systems. For test kits for other
Glenair high performance ber optic connection systems, please consult factory.
Rev. 10.23.19
www.glenair.com E-Mail: sales@glenair.com
GLENAIR, INC. 1211 AIR WAY GLENDALE, CA 91201-2497 818-247-6000 FAX 818-500-9912
L
L-35
© 2012 Glenair, Inc. U.S. CAGE Code 06324 Printed in U.S.A.
Test Probes
and Kits
GTK3000
Glenair Fiber Optic Testing Kit
for ARINC 801 Fiber Optic Connection Systems
Eective use of Glenair ber optic test equipment
Single channel
connector of
choice
FO4309
FA861
Test Probe Jumper
Optical light sourceOptical power
meter
Test Probes
Calibration Adapter
180-173-2 Keyed
180-154M Non-keyed
Step 1: “Zeroing-out optical power meter and light source
The rst step in using the optical test probes is to install each end of the probe cable assembly to the optical
power meter and light source. Next, insert each probe into the calibration adapter.
The test probe loss can now be recorded as a reference measurement or may be “zeroed-out.”
Step 2: Performing optical measurement
Now you are ready to perform optical measurements on the ber optic cable harness. First, select the proper
Glenair D38999 Series III Probe Adapter.
Now, mate or couple the adapters to each end of the cable harness. Next, insert each probe in the appropriate
channel to be tested by pushing on the knurled area on the test probes. Read and record the optical
performance.
To measure the next channel, remove the test probe by pushing on the large diameter of the test probe. The
probe can now be removed and inserted into the next channel. Re-establishing or verication of reference can
be performed at any time by following Step 1.
Single Channel
Connector
of Choice
Test Probe
Cable Assembly
To Be Tested
Optical
Power
Meter
Optical
Light
Source
Test Probe
Test Probe
Adapter
187-214
Test Probe
Adapter
187-214
Test Probe Jumper Assembly
FO4309
FA861
Rev. 10.23.19