www.moxa.com
1
EDS-316 Series
16-port unmanaged Ethernet switches
Features and Benefits
Relay output warning for power failure and port break alarm
Broadcast storm protection
-40 to 75°C operating temperature range (-T models)
Certifications
Introduction
The EDS-316 Ethernet switches provide an economical solution for your industrial Ethernet connections. These 16-port switches come with a built-
in relay warning function that alerts network engineers when power failures or port breaks occur. In addition, the switches are designed for harsh
industrial environments, such as the hazardous locations defined by the Class 1 Div. 2 and ATEX Zone 2 standards.
The switches comply with FCC, UL, and CE standards and support either a standard operating temperature range of -10 to 60°C or a wide
operating temperature range of -40 to 75°C. All switches in the series undergo a 100% burn-in test to ensure that they fulfill the special needs of
industrial automation control applications. The EDS-316 switches can be installed easily on a DIN rail or in a distribution box.
Specifications
Input/Output Interface
Alarm Contact Channels 1 relay output with current carrying capacity of 1 A @ 24 VDC
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector) EDS-316 Series: 16
EDS-316-MM-SC/MM-ST/MS-SC/SS-SC Series, EDS-316-SS-SC-80: 14
EDS-316-M-SC/M-ST/S-SC Series: 15
All models support:
Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection
100BaseFX Ports (multi-mode SC connector) EDS-316-M-SC: 1
EDS-316-M-SC-T: 1
EDS-316-MM-SC: 2
EDS-316-MM-SC-T: 2
EDS-316-MS-SC: 1
100BaseFX Ports (multi-mode ST connector) EDS-316-M-ST Series: 1
EDS-316-MM-ST Series: 2
100BaseFX Ports (single-mode SC connector) EDS-316-MS-SC, EDS-316-S-SC Series: 1
EDS-316-SS-SC Series: 2
100BaseFX Ports (single-mode SC connector, 80
km)
EDS-316-SS-SC-80: 2
www.moxa.com
2
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
Optical Fiber
100BaseFX
Multi-Mode
Single-Mode
(40 km)
Single-Mode
(80 km)
Fiber Cable Type OM1
50/125 µm
G.652 G.652
800 MHz x
km
Typical Distance 4 km 5 km 40 km 80 km
Wavelength
Typical (nm) 1300 1310 1550
TX Range
(nm)
1260 to 1360 1280 to 1340 1530 to 1570
RX Range
(nm)
1100 to 1600 1100 to 1600 1100 to 1600
Optical
Power
TX Range
(dBm)
-10 to -20 0 to -5 0 to -5
RX Range
(dBm)
-3 to -32 -3 to -34 -3 to -34
Link Budget
(dB)
12 29 29
Dispersion
Penalty (dB)
3 1 1
Note: When connecting a single-mode fiber transceiver, we recommend using an
attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link
budget (dB) > dispersion penalty (dB) + total link loss (dB).
DIP Switch Configuration
Ethernet Interface Port break alarm
Switch Properties
Packet Buffer Size 1.25 Mbits
MAC Table Size 4 K
Processing Type Store and Forward
Power Parameters
Input Current Non-fiber models: 0.34 A @ 24 VDC
Fiber models: 0.4 A @ 24 VDC
Connection 1 removable 6-contact terminal block(s)
Operating Voltage 9.6 to 60 VDC
Input Voltage 12/24/48 VDC, Redundant dual inputs
Reverse Polarity Protection Supported
Overload Current Protection Supported
Physical Characteristics
Housing Metal
IP Rating IP30