FLOW, LEVEL AND ENVIRONMENTAL
497
ANSI Flange Size 22
1
2 34568
Overload Flow Rate q
s
[GPM] 130 220 350 530 880 1320 1585
Nominal Flow Rate q
p
[GPM] 65 110 175 265 440 660 1100
Transitional Flow Rate q
t
[GPM] 13 22 35 53 88 132 220
Minimum Flow Rate q
min
[GPM] 2 3.3 5.3 8 13.2 20 33
Pulse Output Constant k
i
[gal/pulse] 51010 15303030
Economical Ultrasonic
Flowmeter for
Water Service
Battery Powered
(Batteries Included)
Displays Flow Rate
and Total
Extended Low
Flow Range
Virtually No
Pressure Loss
No Moving Parts for
Long Life
3-Point Calibration
Included
The FDT100 Series comprises
advanced-technology water
flowmeters. This series uses
transit-time ultrasonic technology in
which the signal is transmitted and
received alternately between 2 flow
sensors and the “time of flight”
determines the flow rate. The
battery-powered transmitter comes
in the user’s choice of an integrally
mounted display or a remote-mount
version. Applications include both
commercial and consumable water
measurement. Long-term stability
and a wide measurement range
make it possible not only to
measure water consumption, but
also to monitor systems for water
leakage. Because the FDT100
Series has no moving parts, system
pressure loss is minimal and
filtration is not required. Display flow
rate or total at the push of a button.
Installation is aided by ANSI or DIN
flanges in sizes from 50 to 200 mm.
IN-LINE ULTRASONIC FLOWMETER
SPECIFICATIONS
Accuracy: ±2% of reading;
±5% below minimum transition rate
Fluid Temperature: 0 to 50°C
Maximum Pressure: 15.8 bar
Enclosure:
IP67 (integral mount version)
Electronic Housing:
Aluminium alloy with plastic cover
FDT100 Series
Starts at
£
1370
FDT103, £1420, shown
smaller than actual size.
GPM Rates
Display:
7-segment, 8-digit, single-line LCD
Current Output: 4 to 20 mA/DC current
(requires 8 to 24 Vdc supply)
Open Collector Output:
5 to 30 Vdc, 1 mA max
Flange: ANSI 150 or DIN
Meter Body: Cast iron
Power Supply:
Internal 3.6V battery (included),
1 to 2 year life
EXCLUSIVELY
FROM
OMEGA!
m
3
/n Rates
DIN Flange Size
32 40 50 65 80 100 125 150 200
Overload Flow
Rate q
s
[m
3
/h]
12 20 30 50 80 120 200 300 360
Nominal Flow
Rate q
p
[m
3
/h]
6 10 15 25 40 60 100 150 250
Transitional Flow
Rate q
t
[m
3
/h]
0.48 0.8 3 5 8 12 20 30 50
Minimum Flow
Rate q
min
[m
3
/h]
0.12 0.2 0.45 0.75 1.2 1.8 3 4.5 7.5
Pulse Output
Constant k
i
[l/pulse]
10 25 25 50 50 100 100 100 100
Remote Version—Basic Dimensions
DN 32 40 50 65 80 100 125 150 200
L: mm 260 300 300 300 350 350 350 350 350
D: mm 140 150 165 185 200 220 250 285 340
Weight: kg 5 7.5 10.5 11.5 15.5 18 23 26.5 37
Compact Version—Basic Dimensions
DN 32 40 50 65 80 100 125 150 200
L: mm 260 300 300 300 350 350 350 350 350
S: mm 190 198 208 225 237 253 280 307 352
D: mm 140 150 165 185 200 220 250 285 340
Weight: kg 4.5 7 10 11 15 17.5 22.5 26 36.5
ULTRASONIC
SENSOR
ELECTRONIC
CONTROL UNIT
PRESSURE
CURRENT OUTPUT
IMPULSE OUTPUT CONST.
warranty
removed
void if
G/imp
ANSI
S/N 22686/06
BN 15 1,45psi
mA
psi
232
5
4-20
2"
136
S
L
ND
D
10
warranty
removed
void if
G/imp
ANSI
S/N 22686/06
BN 15 1,45psi
mA
psi
232
5
4-20
2"
61
80
D
90
max length: 5 m
ELECTRONIC
SENSOR
ULTRASONIC
SENSOR
TERMINAL BOARD
PRESSURE
CURRENT OUTPUT
IMPULSE OUTPUT CONST.
DN
61
5.5
11
61
84
136
4
Dimensions: mm
Dimensions: mm
498