Technical Data Sheet
Zhejiang Zhaolong Interconnect Technology Co., Ltd Tel: +86-(0)572-8075609 Fax: +86-(0)572-8063125
Shilin Industrial Zone, Xinshi, Deqing, Zhejiang, P.R. China www.zhaolong.com.cn
ZLWI-05-53-B05 Form Edition: A/03 Page 1 Effective Date of Form2020-02-29
P/N: ZL5201026
LONGTRONIC
®
Industrial Cable Profinet C PUR
4x22AWG/19
Revision: A/04
Date: 2020-04-28
Description
The cable is used for data transmission with characteristic impedance of 100ohm.
Double screened design supported excellent EMC performance. Application for moved installation.
22AWG/19 TC conductor, HDPE insulation, Mylar tape, LSZH inner jacket, AL/Mylar and tinned copper
braiding overall screen, Non-woven, PUR outer jacket
Design
Conductor
19*0.15mm stranded tinned copper wire
Insulation
HDPE
OD:1.50±0.05mm
Color:
Pair 1:White, Blue
Cabling
Four wires stranded together to a quad
Tape
Mylar tape
Inner jacket
LSZH
Overall screen
AL/Mylar
Tinned copper braiding,coverage 85%
Tape
Non-woven
Outer jacket
PUR
Color :Green(Similar to RAL6018)
Thickness: approx 0.85mm
OD:6.5± 0.3mm
Marking:
ZHAOLONG□LONGTRONIC®ETHERNETPROFINETTYPEC4x22AWGPUR
□□E324007 AWM2132980 600VFT2XXXXXX
****m
Technical Data Sheet
Zhejiang Zhaolong Interconnect Technology Co., Ltd Tel: +86-(0)572-8075609 Fax: +86-(0)572-8063125
Shilin Industrial Zone, Xinshi, Deqing, Zhejiang, P.R. China www.zhaolong.com.cn
ZLWI-05-53-B05 Form Edition: A/03 Page 2 Effective Date of Form2020-02-29
Electrical Characteristics(20)
Conductor DC resistance:
60ohm/km
Operating voltage:
600V
Dielectric Strength:
DC1.5KV for 1min
IEC 61156-5 (section6.2)
Delay Skew:
20ns/100m
Coupling attenuation:
80dB @30-100MHz
Transmission performance:
ISO/IEC 11801 Edition 2.0, IEC 61156-1, IEC 61156-6
Transmission Characteristics(20)
Reference specification:
ISO/IEC 11801 Edition 2.0, IEC 61156-1, IEC 61156-6
Characteristic impedance:
100± 5 ohm@100MHz
Frequency
MHz
ATT
RL
NEXT
PSNEXT
Phase Delay
dB/100m
dB
dB
dB
ns/100m
Max.
Min.
Min.
Min.
Max.
*1
2.4
20.0
65.3
62.3
570.0
4
4.9
23.0
56.3
53.3
552.0
8
6.9
24.5
51.8
48.8
546.7
10
7.8
25.0
50.3
47.3
545.4
16
9.9
25.0
47.2
44.2
543.0
20
11.1
25.0
45.8
42.8
542.0
25
12.5
24.2
44.3
41.3
541.2
31.25
14.1
23.3
42.9
39.9
540.4
62.5
20.4
20.7
38.4
35.4
538.6
100
26.4
19.0
35.3
32.3
536.6
NOTE: (*)The cable performance between 1 MHz and 4 MHz is achieved by design only and it is therefore not
necessary to test for this performance below 4 MHz.
Other Characteristics
Operating temperature:
-40 to 80
Installation temperature:
-20 to 60
Min bending radius:
Fixed: 4D( Cable diameter)
Moving: 8D( Cable diameter)
Halogen free:
IEC 60754-1, IEC 60754-2
Oil resistance:
UL 758 section15; JIS C 3005 type B
UV resistance:
UL 1581 section1200
Flame resistance:
FT2, IEC 60332-1-2
Tensile performance of the cable:
Max. 50N
Crush test of the cable:
Max. 3000N
Note:
1.
means blank;
2. XXXXXX means batch number;
3. ****m means meter