Receiver Protectors
Beverly Microwave Division
150 Sohier Road • Beverly, MA U.S.A. 01915
+1(978) 922-6000 • bmdmarketing@cpii.com
www.cpii.com/bmd
Features:
• Passive operation protects even if system
is turned off
• High power, high duty cycle operation
• Small contribution to system noise figure
• Low leakage protects even the most
sensitive receivers
• Very fast recovery time ensures stable target
detection at minimum range
• Integral multi-function capability available for
improved performance at reduced cost
• Long operating and storage life available
Benefits:
• World’s largest manufacturer of receiver
protectors
• State of the art facility with high level of vertical
integration
• Extensive high power test capability
• In-house environmental test facility
• Computer modeling and automatic test
capabilities
Applications:
• Ground based radars
Airborne radars
• Missile seekers
• Naval radars
• Unmanned aerial vehicles (UAV)
• Solid State Power Amplifiers • Integrated Microwave Assemblies
• Receiver Protectors • Control Components • Transmitters • Amplifiers
• Modulators • Magnetrons • Crossed Field Amplifiers
• Ring Loop Traveling Wave Tubes • Power Couplers
• Solid State Power Amplifiers • Integrated Microwave Assemblies
• Receiver Protectors • Control Components • Transmitters • Amplifiers
• Modulators • Magnetrons • Crossed Field Amplifiers
• Ring Loop Traveling Wave Tubes • Power Couplers
• Weather radars
Air traffic control radars
• Navigation radars
• Fire control radars
Solid state limiters, TR limiters,
Pre-TR Limiters, Pre-TR tubes, TR tubes,
ATR tubes, Multipactors
Receiver Protectors, cont’d
Please note: The data below indicate typically achievable limits for receiver protectors in each frequency
band. The actual combination of performance characteristics which may be realized for any specic device
will depend on the design trade-os required for its particular system application.
Beverly Microwave Division
150 Sohier Road • Beverly, MA U.S.A. 01915
+1(978) 922-6000 • bmdmarketing@cpii.com
www.cpii.com/bmd
RP DATA SHEET PG. 2
General Performance Characteristics
F
requency band VHF/UHF L S C X Ku K Ka
B
andwidth (%) >15 >15 >12 >12 >12 >12 >10 >8
P
eak Power handling (kW) 1000 1000 1000 1000 250 250 100 100
A
verage power handling
(
kW)
50 50 45 20 10 5 2 1
D
uty cycle >10 >10% >10% >10% >10% >10% >10% >10%
P
ulsewidth (uSec) >200 >200 >200 >200 >200 >200 >200 >200
V
SWR 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.5:1 1.5:1
I
nsertion loss (dB) <0.5 <0.5 <0.6 <0.8 <1.0 <1.5 <1.8 <2.0
F
lat leakage power (mW) 20 <20 <20 <20 <20 <20 <20 <20
S
pike leakage power (mW) 100 <100 <100 <100 <100 <100 <100 <100
3
dB Recovery time (uSec) <1.0 <1.0 <1.0 <0.5 <0.1 <0.1 <0.1 <0.13 dB