| Introduction |
The FUM05B flowmeter can be virtually applied to a wide range of long-term online measurement.
Converter IP rating IP67, transducer IP rating IP68. A variety of liquid applications can be accommodated:
ultra-pure liquids, potable water, chemicals, raw sewage, reclaimed watere, cooling water, river water, plant,
effluent.etc
Flow-FUM05B
| Features |
| Applications |
Oil and gas industries / Chemical / Pharmaceutical / Food and beverage / Metal / Mining / Pulp and paper /
Wastewater industries
Measurement accuracy 1%
Converter IP rating IP 67, transducer IP rating IP 68
Wide measurement range, pipe size from DN15 mm to DN6000 mm
Connect the temperature transducer can finish the heat / energy measurement
FUM05B
Ultrasonic Flow Meter
www.eyc-tech.com
Supply Pipe
Return Pipe
No need to cut off water, no pressure loss
Connect clamp-on temperature ,
transducer, can finish the heat / energy
measurement
Easy for installation
Flow Measurement Heat Measurement Features
| Measuring Diagram-Clamp |
| Specification |
*Please make sure the product and the device which connect with RS-485 are on common ground, avoid damaged product.
Flow-FUM05B
www.eyc-tech.com
DC 8 ... 36 V;AC 85 ... 264 V
1.5 W
Steel, Stainless Steel, Cast Iron, Copper, Cement, Pipe, PVC,
Aluminum, Glass steel product, liner is allowed
15 ... 6000 mm
Transmitter installation should be satisfied : upstream 10 D,
downstream 5D, 30D from the pump
Converter : -20 ... 60°C
Flow transducer : -30 ... +160°C
Converter : 85%RH
Flow transducer : Water depth ≦ 2m
Twisted-pair cable, generally, the length
under 50 meters;Select the RS-485,
transmission distance can over 1000 m
132x150x85 mm (Converter)
Converter
Principle
Accuracy
Data interface
Signal output
Signal input
Display
Measuring medium
Type of liquid
Temperature
Turbidity
Flow rate
Electrial
Power supply
Power consumption
Installation
Pipe material
Pipe diameter
Straight pipe
Environmental
Temp. Operating
Humid. Operating
Material
Special cable
Dimension
Transit-time Ultrasonic Flow Meter
±1%
Insulate RS-485, support the Modbus
● 4 ... 20 mA, electrical resistance 0 ... 1 K, accuracy 0.1%
● OCT pulse output (pulse width ... 1000 ms, default is 200 ms)
● Relay output
● 4 ... 20 mA, accuracy 0.1%
● Connect the temperature transducer Pt100
2x20 character LCD with backlight
Single liquid can transmit sound wave
-30 ... +160°C
≦10000 ppm (Less bubble)
0 ... ±10 m/s