©2018 Advanced Energy Industries, Inc.
The UltraVolt
��
10A and 15A series of regulated
DC-to-DC converters provide general purpose high
voltage power for a wide range of applications.
PRODUCT HIGHLIGHTS
Regulated 0 to 10 kV or 0 to 15 kV DC high voltage output
Single output: positive and negative polarity models
Choice of 4, 15, or 30 W maximum output power
12 or 24 VDC input
Maximum Iout capability down to 0 VDC
Output ripple performance as low as 80 ppm (0.8 Vpp)
Available temperature coefficients to 25 ppm/°C
Ease of installation with PCB or chassis-mount options
Simplified integration with available 0 to 5 VDC or 0 to 10 VDC interface
Reliable modular design
Factory-configured performance, control, and integration options
UL/CUL recognized, CE mark, IEC, and RoHS compliant
TYPICAL APPLICATIONS

DC to high voltage DC bias supplies for general purpose uses

High-potential testing

PMT/APD detectors and optical spectrometers

Electrostatics, electrophoresis, and electrospray

Mass spectrometers
Maximum Output Voltage
10 or 15 kV DC
Maximum Output Power
30 W
Type
Single Output
Ripple
To 80 ppm (0.8 Vpp)
Control Interface
Analog
Temperature Coefficient
To 25 ppm/°C
AT A GLANCE
ULTRAVOLT 10A AND 15A SERIES
PRECISION DC TO HIGH VOLTAGE DC CONVERTERS
2 advanced-energy.com
ULTRAVOLT 10A AND 15A SERIES
ELECTRICAL SPECIFICATIONS
Model 10A Series 15A Series
High Voltage Output Range (Adjustable Regulated, Positive or Negative) 0 to 10,000 VDC 0 to 15,000 VDC
High Voltage Outputs Single Single
Input Voltage (VDC, Nominal) 12 VDC 24 VDC 12 VDC 24 VDC
Power Output (Watts, Nominal) 4 W 15 W 30 W 4 W 15 W 30 W
DC Input
Vin (Input Voltage) Range VDC (positive polarity only) 11 to 16 23 to 30 11 to 16 23 to 30
Vin (Nominal) VDC 12 24 12 24
Iin (Input Current, Nominal) A @ 100% HVout, 100% LOAD < 0.5 < 1.5 < 1.6 < 0.5 < 1.5 < 1.6
A @ 100% HVout, 0% LOAD < 0.2 < 0.25 < 0.25 < 0.2 < 0.25 < 0.25
A @ disable/standby state < 0.03 < 0.03
DC Output
HVout (Output Voltage) VDC (positive polarity models = +HVout) 0 to +10,000 0 to +15,000
VDC (negative polarity models = -HVout) 0 to -10,000 0 to -15,000
Iout (Output Current) mA (max) @ 0 to 100% HVout, Vin (nominal) 0.40 1.5 3.0 0.26 1.0 2.0
Pout (Output Power) Watts (max) 4 15 30 4 15 30
Ripple
,
ppm (standard configuration) < 120 < 400 < 760 < 240 < 430 < 800
ppm (with -F-M option) < 80 < 340 < 720 < 210 < 280 < 730
ppm (with -F-M-C option) < 200 < 300 < 500 < 200 < 300 < 500
Vpp (standard configuration) < 1.2 < 4 < 7.6 < 3.6 < 6.5 < 12
Vpp (with -F-M option) < 0.8 < 3.4 < 7.2 < 3.2 < 4.2 < 11
Vpp (with -F-M-C option) < 2 < 3 < 5 < 3 < 4.5 < 7.5
1
Standard product specifications shown unless noted. Custom configurations are available.
2
Nominal ripple measured @ 100% HVout, 100% LOAD into 300 pf bypass capacitor. Valid for 10 to 100% HVout range.
3
ppm = parts per million @ 100% HVout. Vpp = VDC peak to peak @ 100% HVout.
Stability and Regulation
Stability 0.01% (100 ppm) @ 100% HVout (after 30 min warmup interval)
0.02% (200 ppm) @ 100% HVout (per 8 h interval)
Line Regulation 0.01% (100 ppm) @ 100% HVout, 100% Pout, Vin (nominal)
Static Load Regulation 0.01% (100 ppm) @ 100% HVout, 0 to 100% LOAD
Temperature Coefficient 50 ppm/°C (standard configuration over operating temperature range)
25 ppm/°C (with -25PPM option over operating temperature range)
Power-On Rise Time < 150 msec @ 100% LOAD, < 50 msec @ 0% LOAD
Contact factory for other options.
Environmental
Operating Temperature Range -40 to 65°C (-40 to 149°F) case temperature
Storage -55 to 105°C (-67 to 222°F) case temperature
Humidity 0 to 95% RH, non-condensing
Altitude Sea level to 3000 m (10,000 ft)
Sea level to high vacuum (with -P3 option)
Regulatory
Certifications UL/cUL recognized, IEC-60950-1, CE mark (LVD and RoHS)