©2018 Advanced Energy Industries, Inc.
T
he HiTek Power
®
MH60 series is a range of versatile high
voltage power supply modules suitable for specification
in OEM equipment. Powered from 24 VDC, they supply up
to 60 W output and allow full range control and
monitoring of output voltage and current. Custom
versions can be produced for specific requirements.
PRODUCT HIGHLIGHTS

Wide angle, high definition CRTs

X-ray equipment

Insulation and materials testing

Projection
HITEK POWER MH60 SERIES
VERSATILE HIGH VOLTAGE POWER SUPPLY MODULES
60 W output power
High reliability
24 VDC powered
Range of outputs available
Positive or negative polarity
Short circuit and flashover protection
Remotely controllable
V and I control
V and I monitor
LED status indication
Low ripple
EU RoHS compliant to 2002/95/EC
marked for EU LV Directive 73/23/EEC
TYPICAL APPLICATIONS
2 advanced-energy.com
HITEK POWER MH60 SERIES
ELECTRICAL SPECIFICATIONS
Parameters Specifications
Output Power 60 W max
Output Voltage 0 to 50 kV depending on model
Output Current 0 to 2 mA depending on model
Input Voltage +24 VDC (±10%)
Input Current 4 A max
Polarity Positive or negative to order
Ripple < 0.05% +10 V peak to peak
Voltage Regulation Line: < 0.01% for a 10% change in input voltage
Load: < 0.01% ±1 V no load to full load
Current Regulation Line: < 0.01% for a 10% change in input voltage
Load: < 0.01% ±1 μA for a 50% voltage change
Voltage Control 0 to 10 V for 0 to 50 kV accuracy 0.25% ±10 V
Current Control 0 to 10 V for 0 to 1.2 mA accuracy 0.25% ±1 μA
Monitors Voltage: 0 to 10 V ±0.25% ±5 mV for 0 to 50 kV
Current: 0 to 10 V ±0.25% ±5 mV for 0 to 1.2 mA
Each monitor has a series output resistor of 1 kΩ
Temperature Coefficent 100 ppm/°C over operating temperature range
Applies to voltage control, voltage monitor and current monitor
Stability ±0.1% over an 8 h period aer 30 min warmup
Operating Temperature 0 to +45°C
Storage Temperature -20°C to +60°C
Humidity 85% max relative humidity non-condensing
Altitude Sea level to 2000 m (6500')
Installation Category 1 (BS EN61010-1)
Pollution Degree 2 (BS EN61010-1)
Control e power supply is operated via the 9-way, D-type connector situated on the rear panel. Full control
and monitoring functions are available by this method.
Cooling Free convection (no fan)
Protection e units are fully protected against flashover and continuous short circuit (no trip).
EMC e MH60 series is intended for installation as a component of a system. Basic EMC filtering is provided.
Safety e MH60 series meets the requirements of the Low Voltage Directive (LVD), 2006/95/EC, by complying
with BS EN61010 when it is installed as a component part of compliant equipment. It is CE marked accordingly.
RoHS e MH60 series meets the requirements of EU Directive 2002/95/EC on the Restriction of use
of certain Hazardous Substances in electrical and electronic equipment (RoHS).